YONGSUNG韩国龙声株式会社 〉〉 凸轮开关类/万能转换开关 〉〉 43PD MOTOR CAM SWITCH 控制马达凸轮开关(YSMC)
产品描述
yongsung韩国龙声株式会社 >> 凸轮开关类/万能转换开关 >> 43pd motor cam switch 控制马达凸轮开关(ysmc)

43pd motor cam switch is equipment to supply electric voltage for control to protection relay, meter ,control
power voltage, etc. due to automatic transference of bus in accordance with connection state of 2nd voltage
of bus p.t in substation double bus structure. 43pd moter cam switch protects occurring malfunction
of equipment in case of manual transference of 2nd voltage.
this equipment applies for auto-control and scada of efficient application of total protection control system.
* applying place of protection relay *
- protection panel for t/l railway line)
- protection panel for bus)
- protection panel for u.f.r)
- system voltage of requiring transference of p.t)
- protection panel for m.tr 154/23kv)
contact rating 250v, 20a
maximum rating voltage 600v
dc open-close volume dc 125v, 20a (50ms)
control power voltage dc 125v (range of using voltage : dc94v ~ dc 156v)
operating electric current below 1.0a
transference speed after inputting external signal, bus is changed a -> b or b ->a
transference time of p.t voltage perfectly is within 2.5sec.
in case of supplying rating control voltage dc 125v
time of transference current after operating switch, bus is changed a -> b or b ->a
transference time of no p.t voltage perfectly is within 2.5sec.
in case of supplying rating control voltage dc 125v
insulation resistance above 50m Ω
mechanical life time above 200,000 times (after operating 1 time, equipment is stopped 5
seconds)
manual control
in case of field test or manual operation requested, pull the handle at pull-out position (manual
operation position) then enable to operate manually
enable to do manual control regardless of contact position of related aux-s/w for remote signal
lighting green led lamp using for indicating manual operating position)
pushing the handle forward at pull-in position (automatic operating position) then led lamp is
changed to red lighting and operated as automatic control
automatic control
using it connected with bus aux-s/w contact as below 43pd connection diagram (drawing1)
when bus aux-s/w is transferred then transferred automatically to (a-b bus) appropriate bus(b bus)
unable to operate at bridge position where bus aux-s/w putted into simultaneously and enable to
operate as bus aux-s/w transference completed.
operated automatically only at pull-in position (automatic operating position) pushing front handle forward
remote control
using contact of remote control after connecting as below 43pd connection diagram (drawing2)
remote control signal uses three contacts such as a-bus, b-bus, off)
enable to operate at automatic control position (pull-in position) and unable to operate at manual
control position (pull-out position).
automatic/remote control
using it connected as below 43pd connection diagram (drawing3))
motion form of automatic control is same as motion form of remote control)
built-in remote control method
pull in the cam switch handle then supply control power voltage to 19 and 20 terminal. at this moment,
check whether green color of led is changed to red color of led pushing handle out after lighting
confirmed)
check remote control pushing handle in center as off position)
check whether the switch handle moves into b-bus when supplying dc+ to no.5 terminal block of cam
switch)
check whether the switch handle moves into a-bus when supplying dc+ to no.7 terminal of cam switch)
check whether the switch handle moves into center position (off) when supplying dc+ to no.9
terminal of cam switch.
ys ft-1
¡ø note
1. contact composition of dc lock is possible to be different according to 43pd model
2. 43pd contact composition is basic contact composition

3. it is able to operate manual control and field test only in case of pulling front handle out

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报
产品留言
标题
内容
联系人
联系电话
电子邮件
公司名称
联系地址
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!