产品标准standard 本产品按GB12972-1991《矿用橡套软电缆》、MT818-1999《煤矿用阻燃电缆》及Q/320282DCE037-2003标准生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。 The product is manufactured according to the standard 《Flexible rubber-sheathed cables for mining purposes》of GB12972-1991,《Flame retardant drade flexible rubber-sheathed cables for mining purposes》of MT818-1999, and Q/320282DCE037-2003, and the same time is also manufactured according to the standard of IEC、English、Germany and America. 适用范围Applications 矿用橡套软电缆适用于工频额定电压U0/U660/1140V及以下矿用动力装置用移动敷设的电缆。 Flexible rubber-sheathed cables for mining purposes of suitable for mining purposes power device with moving installation and rated voltage up to and including 660/1140V. 使用特性Operating characteristics ● 工频额定电压U0/U为380/660V、660/1140V。 Rated power-frequency voltage U0/U:380/660V and 660/1140V。 ● 电缆导体的*高允许工作温度:65℃ Max. admissible operating temperature of the conductor:65℃ ● 电缆允许*低的工作环境温度为-35℃ Permissible long-term operating temperature: Lowest working temperature is :-35℃ ● 电缆弯曲半径:The bending radius of cable D≤25mm.: ≥4D D>25mm.: ≥6D (D—Diameter of the cable). |
型号.名称Type and Designation
| 型号 Type |
名称 Designation |
U UY MY |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套矿用移动橡套软电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible cables forming purposes. |
UP UY P MYP |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套矿用屏蔽移动橡套软电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible shielding cables forming purposes. |
UC MC |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套采煤机软电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible coal cutter cables forming purposes. |
UCP MCP UCPQ |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套采煤屏蔽软电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible coal cutter shielding cables forming purposes. |
UZ UZP MZ MZP |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套矿用电钻电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible drill cables forming purposes. |
UYQ MYQ |
天然丁苯橡皮绝缘(阻燃)氯丁橡皮护套矿用轻型软电缆 NR/SBR rubber insulated Flame retardant grade neoprene(CR) rubber sheathed flexible light-duty cables forming purposes. | |
生产范围 Production range of cable
| 型号 Type |
额定电压 Rated voltages V |
芯数 NO.of cores |
标称截面 Nominal cross-sectional area mm2 |
| 主线 Principal line |
地线 Ground wire |
控制线 Controlled line |
| U* |
1000 |
3 |
1 |
1 |
2.5~70 |
| UP* |
1000 |
3 |
1 |
1 |
2.5~70 |
UY ● MY |
380/660 |
3 |
1 |
— |
4~70 |
UYP ● MYP |
380/660 |
3 |
1 |
— |
4~70 |
UYP ● MYP |
660/1140 |
3 |
1 |
— |
4~70 |
| UC* |
1000 |
3 |
1 |
2~7 |
10~50 |
UC ● MC |
380/660 |
3 |
1 |
3~7 |
16~50 |
| UCP* |
1000 |
3 |
1 |
2~7 |
10~50 |
UCP ● MCP |
380/660 |
3 |
1 |
3~7 |
16~50 |
| UCPQ* |
1140 |
3 |
1 |
3 |
35~70 |
UCP ● MCP |
660/1140 |
3 |
1 |
3 |
35~95 |
UZ ● UZP ● MZ MZP |
300/500 |
3 |
1 |
1 |
2.5~4 |
UYQ ● MYQ |
300/500 |
2~12 |
— |
— |
1.0~2.5 | |
注:“●”的产品按GB12792-1991标准生产。 “*”的产品按Q/320282DCE037-2003标准生产。 其余产品按MT818-1999标准生产。 Note: “●”indicates that the product is manufactured according to the standard of GB12972-1991 “*”indicates that the product is manufactured according to the standard of Q/320282DCE037-2003. The rest product is manufactured according to the standard of MT818-1999.
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动橡套软电缆 Flexible rubber-sheathed cables for mining purposes 型号(Type):U 额定电压(Rating Voltage):1000V |
 |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:Q/320282DCE037-2003。 3、U型电缆有4芯和5芯两种结构,有3根主线芯和一根地线芯组成(5芯电缆中有一芯为控制线),围绕垫芯绞合成缆,外面挤包氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线白色。 7、成缆:主线芯、地线、控制线围绕橡皮垫芯按右向绞合成缆。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型U型成品电缆具有不延燃性能,阻燃型U型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动橡套软电缆 Flexible rubber-sheathed cables for mining purposes 型号(Type):MY 额定电压(Rating Voltage):380/660V
| 芯数截面 Nom.cross sectional areas mm2 |
导体结构 Conductor structure NO./mm |
绝缘厚度 Insulation thickness mm |
护套厚度 Sheath thickness mm |
电缆外径 Average diameter |
参考重量 Cable approx. weight kg/km |
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃载流量 Current carring capacity(20 ℃ ) A |
| 标称 Normianal mm |
*大 Max mm |
| 3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
20.9 |
23.0 |
637 |
4.950 |
35 |
| 56/0.30 |
4.950 |
| 3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
22.9 |
25.1 |
856 |
3.300 |
46 |
| 84/0.30 |
3.300 |
| 3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
27.8 |
30.6 |
1304 |
1.910 |
64 |
| 84/0.40 |
1.910 |
| 3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
30.3 |
33.3 |
1545 |
1.210 |
85 |
| 84/0.40 |
1.910 |
| 3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
36.4 |
40.1 |
2269 |
0.780 |
113 |
| 126/0.40 |
1.210 |
| 3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
40.5 |
44.6 |
2786 |
0.554 |
138 |
| 126/0.40 |
1.210 |
| 3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
45.5 |
50.1 |
3554 |
0.386 |
173 |
| 126/0.40 |
1.210 |
| 3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
51.5 |
55.1 |
4587 |
0.272 |
215 |
| 196/0.40 |
0.780 | |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:MT818.5-1999。 3、MT型电缆有4芯和5芯两种结构,有3根主线芯和一根地线芯组成(5芯电缆中有一芯为控制线),围绕垫芯绞合成缆,外面挤包氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色。 7、成缆:主线芯、地线、围绕橡皮垫芯按右向绞合成缆。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。护套橡皮的氧指数≥40。 9、成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动橡套软电缆 Flexible rubber-sheathed cables for mining purposes 型号(Type):UY 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 4+1 × 4
|
56/0.30
|
1.4
|
3.5
|
20.3
|
23.4
|
637
|
4.950
|
35
|
56/0.30
|
4.950
|
3 × 6+1 × 6
|
84/0.30
|
1.4
|
3.5
|
23.0
|
26.4
|
856
|
3.300
|
46
|
84/0.30
|
3.300
|
3 × 10+1 × 10
|
84/0.40
|
1.6
|
4.0
|
27.5
|
31.3
|
1304
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.6
|
4.0
|
29.6
|
33.4
|
1545
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
1.8
|
4.5
|
35.6
|
39.8
|
2269
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
1.8
|
4.5
|
38.7
|
42.9
|
2786
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.0
|
5.0
|
43.6
|
47.9
|
3554
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.0
|
5.0
|
49.7
|
54.4
|
4587
|
0.272
|
215
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:GB12972.5-1991。 3、UY型电缆是有3根主线芯和一根地线芯组成围绕垫芯绞合成缆,外面挤包氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白、地线黑色。 7、成缆:主线芯、地线、围绕橡皮垫芯按右向绞合成缆。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型UY型成品电缆具有不延燃性能,阻燃型UY型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):UP 额定电压(Rating Voltage):1000V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 4+1 × 4
|
56/0.30
|
1.4
|
3.5
|
23.7
|
26.1
|
730
|
4.950
|
35
|
56/0.30
|
1.4
|
4.950
|
3 × 4+1 × 4+1 × 4
|
56/0.30
|
1.4
|
3.5
|
26.7
|
29.4
|
825
|
4.950
|
35
|
56/0.30
|
1.4
|
4.950
|
56/0.30
|
1.4
|
4.950
|
3 × 6+1 × 6
|
84/0.30
|
1.4
|
3.5
|
25.2
|
27.7
|
959
|
3.300
|
46
|
84/0.30
|
1.4
|
3.300
|
3 × 10+1 × 6
|
84/0.40
|
1.6
|
4.0
|
29.6
|
32.6
|
1344
|
1.910
|
64
|
84/0.30
|
1.6
|
3.300
|
3 × 16+1 × 6
|
126/0.40
|
1.6
|
4.0
|
32.6
|
35.9
|
1593
|
1.210
|
85
|
84/0.30
|
1.6
|
3.300
|
3 × 25+1 × 10
|
196/0.40
|
1.8
|
4.5
|
38.0
|
41.0
|
2332
|
0.780
|
113
|
84/0.40
|
2.5
|
1.910
|
3 × 35+1 × 10
|
276/0.40
|
1.8
|
4.5
|
41.5
|
44.8
|
2864
|
0.554
|
138
|
84/0.40
|
2.5
|
1.910
|
3 × 50+1 × 10
|
396/0.40
|
2.0
|
5.0
|
46.5
|
49.8
|
3652
|
0.386
|
173
|
84/0.40
|
2.5
|
1.910
|
3 × 70+1 × 16
|
360/0.50
|
2.0
|
5.0
|
51.5
|
55.1
|
4689
|
0.272
|
215
|
126/0.40
|
2.9
|
1.210
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:Q/320282DCE037-2003。 4、UP型电缆有4芯和5芯两种结构,有3根主线芯和一根地线芯组成(5芯电缆中有一芯为控制线),围绕垫芯绞合成缆,外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线白色。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包半导电带。 10、成缆:主线芯、地线、控制线围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UP型成品电缆具有不延燃性能,阻燃型UP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):MYP 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 4+1 × 4
|
56/0.30
|
1.4
|
3.5
|
22.9
|
25.2
|
730
|
4.950
|
35
|
56/0.30
|
4.950
|
3 × 6+1 × 6
|
84/0.30
|
1.4
|
3.5
|
24.7
|
27.2
|
959
|
3.300
|
46
|
84/0.30
|
3.300
|
3 × 10+1 × 10
|
84/0.40
|
1.6
|
4.0
|
29.7
|
32.7
|
1427
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.6
|
4.0
|
32.2
|
35.4
|
1675
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
1.8
|
4.5
|
38.3
|
41.0
|
2419
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
1.8
|
4.5
|
42.4
|
46.6
|
2952
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.0
|
5.0
|
47.4
|
51.0
|
3741
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.0
|
5.0
|
52.4
|
57.1
|
4790
|
0.272
|
215
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:MT818.5-1999。 4、MYP型电缆有3个带绝缘屏蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包半导电带。 10、成缆:3个主线芯1个地线围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。护套橡皮的氧指数≥40。 12、成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):UYP 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 4+1 × 4
|
56/0.30
|
1.4
|
3.5
|
23.7
|
27.2
|
730
|
4.950
|
35
|
56/0.30
|
4.950
|
3 × 6+1 × 6
|
84/0.30
|
1.4
|
3.5
|
26.4
|
30.1
|
959
|
3.300
|
46
|
84/0.30
|
3.300
|
3 × 10+1 × 10
|
84/0.40
|
1.6
|
4.0
|
30.9
|
34.7
|
1427
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.6
|
4.0
|
33.0
|
36.8
|
1675
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
1.8
|
4.5
|
39.0
|
43.2
|
2419
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
1.8
|
4.5
|
42.1
|
46.3
|
2952
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.0
|
5.0
|
47.1
|
51.4
|
3741
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.0
|
5.0
|
52.4
|
57.1
|
4790
|
0.272
|
215
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:GB12972.5-1991。 4、UYP型电缆有3个带绝缘屏蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白,地线黑色。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包覆半导电橡皮。 10、成缆:3个主线芯1个地线围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。抗撕裂性能不低于7.5N/mm。 12、普通型UYP型成品电缆具有不延燃性能,阻燃型UYP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):UPQ 额定电压(Rating Voltage):1140V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 10+1 × 10
|
84/0.40
|
1.8
|
4.5
|
31.7
|
34.9
|
1640
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.8
|
4.5
|
34.2
|
37.6
|
1899
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
2.0
|
5.0
|
40.3
|
44.3
|
2648
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
2.0
|
5.0
|
44.4
|
48.8
|
3201
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.2
|
5.5
|
51.5
|
54.6
|
4013
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.2
|
5.5
|
53.9
|
59.3
|
5079
|
0.272
|
215
|
196/0.40
|
0.780
|
3 × 95+1 × 25
|
475/0.50
|
2.4
|
6.0
|
62.1
|
68.1
|
6280
|
0.206
|
260
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:Q/320282DCE037-2003。 4、UPQ型电缆有3个带绝缘屏蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黄色氯化聚乙烯橡皮护套或黄色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线芯黑色。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包半导电带。 10、成缆:3个主线芯和一个地线围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。护套橡皮的氧指数≥40。抗撕裂性能不低于7.5N/mm。 12、成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):MYP 额定电压(Rating Voltage):660/1440V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 10+1 × 10
|
84/0.40
|
1.8
|
4.5
|
31.7
|
34.9
|
1640
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.8
|
4.5
|
34.2
|
37.6
|
1899
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
2.0
|
5.0
|
40.3
|
44.3
|
2648
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
2.0
|
5.0
|
44.4
|
48.8
|
3201
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.2
|
5.5
|
51.5
|
54.6
|
4013
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.2
|
5.5
|
53.9
|
59.3
|
5079
|
0.272
|
215
|
196/0.40
|
0.780
|
3 × 95+1 × 25
|
475/0.50
|
2.4
|
6.0
|
62.1
|
68.1
|
6280
|
0.206
|
260
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:MT818.5-1999. 4、MYP型电缆有3个带绝缘屏蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黄色氯化聚乙烯橡皮护套或黄色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线芯黑色。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包半导电带。 10、成缆:3个主线芯和一个地线围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。护套橡皮的氧指数≥40。 12、成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动屏蔽橡套软电缆 Flexible shielding rubber-sheathed cables for mining purposes 型号(Type):UYP 额定电压(Rating Voltage):660/1140V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 10+1 × 10
|
84/0.40
|
1.8
|
4.5
|
32.4
|
36.2
|
1640
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.8
|
4.5
|
34.6
|
38.4
|
1899
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 25+1 × 16
|
196/0.40
|
2.0
|
5.0
|
41.1
|
45.3
|
2648
|
0.780
|
113
|
126/0.40
|
1.210
|
3 × 35+1 × 16
|
276/0.40
|
2.0
|
5.0
|
44.2
|
48.4
|
3201
|
0.554
|
138
|
126/0.40
|
1.210
|
3 × 50+1 × 16
|
396/0.40
|
2.2
|
5.5
|
49.1
|
53.4
|
4013
|
0.386
|
173
|
126/0.40
|
1.210
|
3 × 70+1 × 25
|
360/0.50
|
2.2
|
5.5
|
55.5
|
60.2
|
5079
|
0.272
|
215
|
196/0.40
|
0.780
|
3 × 95+1 × 25
|
475/0.50
|
2.4
|
6.0
|
61.2
|
65.9
|
6280
|
0.206
|
260
|
196/0.40
|
0.780
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:GB12972.5-1991。 4、UYP型电缆有3个带绝缘屏.蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黄色氯化聚乙烯橡皮护套或黄色氯丁橡皮护套。 5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色。 8、地线:采用半导电橡皮包覆。 9、绝缘屏蔽:在绝缘表面包覆半导电橡皮。 10、成缆:主线芯、地线、围绕半导电橡皮垫芯按右向绞合成缆。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。抗撕裂性能不低于7.5N/mm。 12、普通型UYP型成品电缆具有不延燃性能,阻燃型UYP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UC 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
31.4
|
35.1
|
1668
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
37.8
|
42.0
|
2324
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
41.8
|
46.0
|
3234
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
46.0
|
50.9
|
4080
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:GB12972.2-1991。 3、UC型电缆,有3根主线芯,一根地线芯和一组控制单元组成(单元组成有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 7、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型UC型成品电缆具有不延燃性能,阻燃型UC型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用屏蔽套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):MC 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
31.3
|
34.4
|
1668
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
38.4
|
41.0
|
2324
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
43.9
|
48.3
|
3234
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
47.7
|
51.0
|
4080
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:GB818.2-1999。 3、MC型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 7、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、MC型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UC 额定电压(Rating Voltage):1000V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 10+1 × 10
|
84/0.40
|
1.6
|
4.5
|
28.3
|
31.1
|
1201
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 10+1 × 10+2 × 10
|
84/0.40
|
1.6
|
4.5
|
33.0
|
36.3
|
1621
|
1.910
|
64
|
84/0.40
|
1.910
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.6
|
4.5
|
31.2
|
34.2
|
1635
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
31.5
|
34.7
|
1668
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 10
|
196/0.40
|
1.8
|
4.5
|
37.1
|
40.2
|
2158
|
0.780
|
113
|
84/0.40
|
1.910
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
37.9
|
40.9
|
2324
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 16
|
276/0.40
|
1.8
|
5.5
|
39.8
|
43.0
|
2764
|
0.554
|
138
|
126/0.40
|
1.910
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
41.2
|
44.5
|
3234
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 16
|
396/0.40
|
2.0
|
5.5
|
44.1
|
47.2
|
3543
|
0.386
|
170
|
126/0.40
|
1.210
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
46.9
|
50.2
|
4080
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、产品标准:Q/320282DCE037-2003。 3、UC型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 7、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型UC型成品电缆具有不延燃性能,阻燃型UC型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UCP 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
34.7
|
38.5
|
1883
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
41.3
|
45.5
|
2571
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
45.1
|
49.3
|
3527
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
50.0
|
54.3
|
4400
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:GB12972.2-1991。 4、UC型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包覆半导电橡皮。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UCP型成品电缆具有不延燃性能,阻燃型UCP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):MCP 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
33.2
|
36.5
|
1883
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
40.3
|
44.3
|
2571
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
45.8
|
50.4
|
3527
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
51.5
|
55.0
|
4400
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:MT818.2-1999。 4、MCP型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包半导电带。 9、地线:挤包半导电橡皮��� 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、MCP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UCP 额定电压(Rating Voltage):1000V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 10+1 × 10
|
84/0.40
|
1.6
|
4.5
|
31.3
|
34.4
|
1333
|
1.910
|
64
|
84/0.40
|
1.910
|
3 × 10+1 × 10+2 × 10
|
84/0.40
|
1.6
|
4.5
|
37.8
|
41.6
|
1784
|
1.910
|
64
|
84/0.40
|
1.910
|
84/0.40
|
1.910
|
3 × 16+1 × 10
|
126/0.40
|
1.6
|
4.5
|
34.4
|
37.8
|
1670
|
1.210
|
85
|
84/0.40
|
1.910
|
3 × 16+1 × 4+3 × 2.5
|
126/0.40
|
1.6
|
4.5
|
35.8
|
39.4
|
1883
|
1.210
|
85
|
56/0.30
|
4.950
|
49/0.25
|
7.980
|
3 × 25+1 × 10
|
196/0.40
|
1.8
|
4.5
|
40.2
|
43.4
|
2320
|
0.780
|
113
|
84/0.40
|
1.910
|
3 × 25+1 × 6+4 × 2.5
|
196/0.40
|
1.8
|
5.5
|
42.7
|
46.1
|
2571
|
0.780
|
113
|
84/0.30
|
3.300
|
49/0.25
|
7.980
|
3 × 35+1 × 16
|
276/0.40
|
1.8
|
5.5
|
42.8
|
46.2
|
2944
|
0.554
|
138
|
126/0.40
|
1.910
|
3 × 35+1 × 6+4 × 4
|
276/0.40
|
1.8
|
5.5
|
45.3
|
48.9
|
3527
|
0.554
|
138
|
84/0.30
|
3.300
|
56/0.30
|
4.950
|
3 × 50+1 × 16
|
396/0.40
|
2.0
|
5.5
|
47.3
|
50.6
|
3745
|
0.386
|
170
|
126/0.40
|
1.210
|
3 × 50+1 × 10+7 × 4
|
396/0.40
|
2.0
|
5.5
|
50.9
|
54.5
|
4400
|
0.386
|
170
|
84/0.40
|
1.910
|
56/0.30
|
4.950
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:Q/320282DCE037-2003。 4、UCP型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元有2芯,3芯,4芯和7芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包半导电带。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UCP型成品电缆具有不延燃性能,阻燃型UCP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UCPQ 额定电压(Rating Voltage):660/1140V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 35+1 × 6+3 × 6
|
276/0.40
|
2.0
|
6.0
|
47.2
|
51.4
|
3758
|
0.554
|
138
|
84/0.30
|
3.300
|
84/0.30
|
3.300
|
3 × 50+1 × 10+3 × 6
|
396/0.40
|
2.2
|
7.0
|
54.3
|
58.6
|
4888
|
0.386
|
170
|
84/0.30
|
1.910
|
84/0.30
|
3.300
|
3 × 70+1 × 16+3 × 6
|
360/0.50
|
2.2
|
7.0
|
59.6
|
64.3
|
5783
|
0.272
|
210
|
126/0.40
|
1.210
|
84/0.30
|
3.300
|
3 × 95+1 × 25+3 × 10
|
475/0.50
|
2.4
|
7.0
|
64.5
|
70.1
|
7430
|
0.206
|
250
|
196/0.40
|
0.780
|
84/0.40
|
1.910
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:Q/320282DCE037-2003。 4、UCPQ型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元3芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包半导电带。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UCPQ型成品电缆具有不延燃性能,阻燃型UCPQ型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):UCP 额定电压(Rating Voltage):660/1140V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 35+1 × 6+3 × 6
|
276/0.40
|
2.0
|
6.0
|
47.2
|
51.4
|
3758
|
0.554
|
138
|
84/0.30
|
3.300
|
84/0.30
|
3.300
|
3 × 50+1 × 10+3 × 6
|
396/0.40
|
2.2
|
7.0
|
54.3
|
58.6
|
4888
|
0.386
|
170
|
84/0.30
|
1.910
|
84/0.30
|
3.300
|
3 × 70+1 × 16+3 × 6
|
360/0.50
|
2.2
|
7.0
|
59.6
|
64.3
|
5783
|
0.272
|
210
|
126/0.40
|
1.210
|
84/0.30
|
3.300
|
3 × 95+1 × 25+3 × 10
|
475/0.50
|
2.4
|
7.0
|
64.5
|
70.1
|
7430
|
0.206
|
250
|
196/0.40
|
0.780
|
84/0.40
|
1.910
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:Q/320282DCE037-2003。 4、UCPQ型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元3芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包半导电带。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UCP型成品电缆具有不延燃性能,阻燃型UCP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 采煤机用橡套软电缆 Flexible coal cutter rubber-sheathed cables for mining purposes 型号(Type):MCP 额定电压(Rating Voltage):660/1140V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 35+1 × 6+3 × 6
|
276/0.40
|
2.0
|
6.0
|
47.2
|
51.4
|
3758
|
0.554
|
138
|
84/0.30
|
3.300
|
84/0.30
|
3.300
|
3 × 50+1 × 10+3 × 6
|
396/0.40
|
2.2
|
7.0
|
54.3
|
58.6
|
4888
|
0.386
|
170
|
84/0.30
|
1.910
|
84/0.30
|
3.300
|
3 × 70+1 × 16+3 × 6
|
360/0.50
|
2.2
|
7.0
|
59.6
|
64.3
|
5783
|
0.272
|
210
|
126/0.40
|
1.210
|
84/0.30
|
3.300
|
3 × 95+1 × 25+3 × 10
|
475/0.50
|
2.4
|
7.0
|
64.5
|
70.1
|
7430
|
0.206
|
250
|
196/0.40
|
0.780
|
84/0.40
|
1.910
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:MT818.2-1999。 4、MCP型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元3芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包半导电带。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。有控制单元的将地线放中心。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、MCP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用电钻电缆 Flexible drill cables for mining purposes 型号(Type):UZ 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
17.8
|
19.6
|
488
|
8.820
|
25
|
77/0.20
|
8.820
|
3 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
19.1
|
21.0
|
602
|
5.390
|
35
|
126/0.20
|
5.390
|
3 × 2.5+1 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
19.1
|
21.0
|
521
|
8.820
|
25
|
77/0.20
|
8.820
|
77/0.20
|
8.820
|
3 × 4+1 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
20.5
|
22.6
|
648
|
5.390
|
35
|
126/0.20
|
5.390
|
126/0.20
|
5.390
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于160MΩ·km。 2、产品标准:GB12972.8-1991。 3、UZ型电缆,有3根主线芯,一根地线芯和一根控制线芯组成,成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色。控制线打号码。 7、成缆:按右向绞合成缆。中心加填芯。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、普通型UZ型成品电缆具有不延燃性能,阻燃型UZ型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用电钻电缆 Flexible drill cables for mining purposes 型号(Type):UZP 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
19.4
|
22.2
|
641
|
8.820
|
25
|
77/0.20
|
8.820
|
3 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
20.8
|
23.6
|
766
|
5.390
|
35
|
126/0.20
|
5.390
|
3 × 2.5+1 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
20.9
|
23.8
|
743
|
8.820
|
25
|
77/0.20
|
8.820
|
77/0.20
|
8.820
|
3 × 4+1 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
22.4
|
25.5
|
909
|
5.390
|
35
|
126/0.20
|
5.390
|
126/0.20
|
5.390
| |
 |
备注: 1、电缆绝缘主线芯��间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:GB12972.8-1991。 4、UZP型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元3芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包覆半导电橡皮。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、普通型UZP型成品电缆具有不延燃性能,阻燃型UZP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用电钻电缆 Flexible drill cables for mining purposes 型号(Type):MZ 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
17.7
|
19.4
|
488
|
8.820
|
25
|
77/0.20
|
8.820
|
3 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
19.1
|
21.0
|
602
|
5.390
|
35
|
126/0.20
|
5.390
|
3 × 2.5+1 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
18.9
|
20.8
|
521
|
8.820
|
25
|
77/0.20
|
8.820
|
77/0.20
|
8.820
|
3 × 4+1 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
20.5
|
22.6
|
648
|
5.390
|
35
|
126/0.20
|
5.390
|
126/0.20
|
5.390
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于160MΩ·km。 2、产品标准:MT818.8-1999。 3、MZ型电缆,有3根主线芯,一根地线芯和一根控制线芯组成,成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色。控制线打号码。 7、成缆:按右向绞合成缆。中心加填芯。 8、护套:采用GB7594.7-1987中XH-03A型橡皮。 9、MZ型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用电钻电缆 Flexible drill cables for mining purposes 型号(Type):MZP 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
3 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
19.5
|
21.5
|
641
|
8.820
|
25
|
77/0.20
|
8.820
|
3 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
21.0
|
23.1
|
766
|
5.390
|
35
|
126/0.20
|
5.390
|
3 × 2.5+1 × 2.5+1 × 2.5
|
77/0.20
|
1.0
|
3.5
|
21.1
|
23.2
|
743
|
8.820
|
25
|
77/0.20
|
8.820
|
77/0.20
|
8.820
|
3 × 4+1 × 4+1 × 4
|
126/0.20
|
1.0
|
3.5
|
22.8
|
25.1
|
909
|
5.390
|
35
|
126/0.20
|
5.390
|
126/0.20
|
5.390
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于160MΩ·km。 2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。 3、产品标准:MT818.8-1999。 4、MZP型电缆,有3根主线芯,一根地线芯和一组控制单元组成(控制单元3芯),成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 5、导电线芯:采用镀锡软铜线,其性能符合 GB/T3956-1997。 6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。地线黑色,控制线打号码。 8、绝缘屏蔽:在绝缘表面包覆半导电橡皮。 9、地线:挤包半导电橡皮。 10、成缆:按右向绞合成缆。无控制单元的中心加填芯。 11、护套:采用GB7594.7-1987中XH-03A型橡皮。 12、MZP型成品电缆的阻燃性能满足MT386-1995的要求。 13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动轻型橡套软电缆 Flexible light-duty rubber-sheathed cables for mining purposes 型号(Type):UYQ 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
2 × 1.0
|
32/0.20
|
0.6
|
1.5
|
9.3
|
10.2
|
100.5
|
19.50
|
16
|
2 × 1.5
|
30/0.25
|
0.8
|
1.5
|
10.8
|
11.8
|
138.3
|
13.30
|
20
|
2 × 2.5
|
49/0.25
|
1.0
|
1.5
|
12.5
|
13.7
|
200.5
|
7.98
|
28
|
3 × 1.0
|
32/0.20
|
0.6
|
1.5
|
9.7
|
10.6
|
116.3
|
19.50
|
13
|
3 × 1.5
|
30/0.25
|
0.8
|
1.5
|
11.4
|
12.5
|
161.8
|
13.30
|
17
|
3 × 2.5
|
49/0.25
|
1.0
|
1.5
|
13.1
|
14.4
|
246.2
|
7.98
|
24
|
4 × 1.0
|
32/0.20
|
0.6
|
1.5
|
10.6
|
11.7
|
141.9
|
19.50
|
12
|
4 × 1.5
|
30/0.25
|
0.8
|
1.5
|
12.3
|
13.5
|
197.5
|
13.30
|
17
|
4 × 2.5
|
49/0.25
|
1.0
|
2.0
|
15.4
|
16.9
|
329.7
|
7.98
|
24
|
7 × 1.0
|
32/0.20
|
0.6
|
1.5
|
12.2
|
13.5
|
212.1
|
19.50
|
11
|
7 × 1.5
|
30/0.25
|
0.8
|
2.0
|
15.4
|
17.0
|
335.1
|
13.30
|
16
|
7 × 2.5
|
49/0.25
|
1.0
|
2.0
|
17.9
|
19.7
|
479.9
|
7.98
|
32
|
12 × 1.0
|
32/0.20
|
0.6
|
2.0
|
16.5
|
18.2
|
335.8
|
19.50
|
11
|
12 × 1.5
|
30/0.25
|
0.8
|
2.5
|
20.5
|
22.6
|
518.1
|
13.30
|
16
|
12 × 2.5
|
49/0.25
|
1.0
|
2.5
|
23.9
|
26.4
|
752.4
|
7.98
|
32
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于160MΩ·km。 2、产品标准:MT12972.8-1991。 3、UYQ型电缆,有2~12根主线芯组成,成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:四芯及以下采用绝缘分色识别,四芯以上采用打印号码识别。 7、成缆:按右向绞合成缆。 8、护套:采用GB7594.7-1987中XH-01A型橡皮。 9、普通型UYQ型成品电缆具有不延燃性能,阻燃型UYQ型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |
结构尺寸及主要技术参数Construction and main technical data ● 矿用移动轻型橡套软电缆 Flexible light-duty rubber-sheathed cables for mining purposes 型号(Type):MYQ 额定电压(Rating Voltage):300/500V
芯数截面 Nom.cross sectional areas mm2
|
导体结构 Conductor structure NO./mm
|
绝缘厚度 Insulation thickness mm
|
护套厚度 Sheath thickness mm
|
电缆外径 Average diameter
|
参考重量 Cable approx. weight kg/km
|
导体(铜)*大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km
|
20 ℃载流量 Current carring capacity(20 ℃ ) A
|
标称 Normianal mm
|
*大 Max mm
|
2 × 1.0
|
32/0.20
|
0.6
|
1.5
|
8.1
|
8.9
|
100.5
|
19.50
|
16
|
2 × 1.5
|
30/0.25
|
0.8
|
1.5
|
9.4
|
10.3
|
138.3
|
13.30
|
20
|
2 × 2.5
|
49/0.25
|
1.0
|
1.5
|
11.5
|
12.7
|
200.5
|
7.98
|
28
|
3 × 1.0
|
32/0.20
|
0.6
|
1.5
|
8.4
|
9.0
|
116.3
|
19.50
|
13
|
3 × 1.5
|
30/0.25
|
0.8
|
1.5
|
9.9
|
10.9
|
161.8
|
13.30
|
17
|
3 × 2.5
|
49/0.25
|
1.0
|
1.5
|
12.1
|
13.4
|
246.2
|
7.98
|
24
|
4 × 1.0
|
32/0.20
|
0.6
|
1.5
|
9.1
|
10.1
|
141.9
|
19.50
|
12
|
4 × 1.5
|
30/0.25
|
0.8
|
1.5
|
10.7
|
11.8
|
197.5
|
13.30
|
17
|
4 × 2.5
|
49/0.25
|
1.0
|
2.0
|
14.3
|
15.7
|
329.7
|
7.98
|
24
|
7 × 1.0
|
32/0.20
|
0.6
|
1.5
|
10.6
|
11.7
|
212.1
|
19.50
|
11
|
7 × 1.5
|
30/0.25
|
0.8
|
2.0
|
13.6
|
15.0
|
335.1
|
13.30
|
16
|
7 × 2.5
|
49/0.25
|
1.0
|
2.0
|
16.8
|
18.4
|
479.9
|
7.98
|
32
|
12 × 1.0
|
32/0.20
|
0.6
|
2.0
|
14.6
|
16.0
|
335.8
|
19.50
|
11
|
12 × 1.5
|
30/0.25
|
0.8
|
2.5
|
18.3
|
20.1
|
518.1
|
13.30
|
16
|
12 × 2.5
|
49/0.25
|
1.0
|
2.5
|
22.7
|
24.9
|
752.4
|
7.98
|
32
| |
 |
备注: 1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于160MΩ·km。 2、产品标准:MT818.9-1999。 3、MYQ型电缆,有2~12根主线芯组成,成缆后外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。 4、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。 5、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。 6、线芯识别:四芯及以下采用绝缘分色识别,四芯以上采用打印号码识别。 7、成缆:按右向绞合成缆。 8、护套:采用GB7594.7-1987中XH-01A型橡皮。 9、普通型UYQ型成品电缆具有不延燃性能,阻燃型UYQ型成品电缆的阻燃性能满足MT386-1995的要求。 10、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。 |