DP6070-7R2控制器 美国omega
1/8 DIN温度面板仪表 DP6070 Series 1/8 DIN温度面板仪表 模块化的USB,RS232,RS485串行通信选项和继电器 J,K,T,E,R,S,B,N,C热电偶 100或1000ù铂,10ù铜,镍120ùRTDS 1或0.1°分辨率 自动冷端补偿 NEMA 4X(IP65)前 通用的85到265 VAC或12 / 24 VDC输入功率 大型双行6-character显示,15和12毫米(0.60和0.46) 阳光下可读的显示模式 2或4个继电器和孤立的4至20 mA输出选项 外部4中继和数字I/O扩展模块 使用自由软件,监控和编程 The DP6070 temperature meter boasts specifications and functionality that clearly makes it one of the most advanced temperature meters available. It’s dual-line 6-character display, function keys, and optional expansion modules are only a few of the special features available. The DP6070 accepts many thermocouple types and RTDs and can be configured to have either a 1° or 0.1° display resolution on any type of sensor input. The lower display makes configuration simpler. The display itself is quite configurable. There are many relay functions for up to 8 relays; including an Interlock Relay function. The 4 to 20 mA output can represent up to 12 different parameters/variables. This makes the DP6070 one of the most versatile meters on the market. Sunlight readable display models have an extraordinarily bright LED display. The upper display can be programmed to indicate current temperature, maximum or minimum temperature, alternating maximum/minimum temperatures, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off. Input selection and configuration are conveniently set up via rear switches and front panel programming. Three levels of password protection help maintain the reliability of the programming. 规格: Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking Upper Display: 15 mm (0.60") high Lower Display: 12 mm (0.46") high Display Intensity: 8 intensity levels Display Update Rate: 5/second (200 ms) Overrange: Display flashes 999999 Underrange: Display flashes -99999 Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input Front Panel: NEMA 4X (IP65) Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function Noise Filter: Programmable from 2 to 199 (0 will disable filter) Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months Max/Min Display: Max (peak)/min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W maximum, or jumper selectable 12/24 Vdc ±10%, 15 W max Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse,br> Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA maximum (standard), (12/24 Vdc powered models rated @ 100 mA maximum); 5 or 10 Vdc @ 50 mA maximum, selectable with internal jumper J4 Normal Mode Rejection: Greater than 60 dB at 50/60 Hz Isolation: 4 kV input/output-to-power line; 500V input-to-output or output-to-P+ supply Overvoltage Category: Installation overvoltage category II, local level with smaller transient overvoltages than installation overvoltage category III Operating Temperature Range: -40 to 65°C (-40 to 149°F) Storage Temperature Range: -40 to 85°C (-40 to 185°F) Relative Humidity: 0 to 90% non-condensing Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm) Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64") Weight: 269 g (9.5 oz) 注释: Comes complete with 2 side mounting brackets and operator’s manual.
产品型号说明: (1) DP6070 - 选项描述 (1) Output 选择 6R0 代表 Temperature panel meter 6R2 代表 Temperature panel meter with 2 relays 6R3 代表 Temperature panel meter with 4 to 20 mA output 6R4 代表 Temperature panel meter with 4 relays 6R5 代表 Temperature panel meter with 2 relays and 4 to 20 mA output 6R7 代表 Temperature panel meter with 4 relays and 4 to 20 mA output 6H0 代表 Temperature panel meter 6H2 代表 Temperature panel meter with 2 relays 6H3 代表 Temperature panel meter with 4 to 20 mA output 7H0 代表 Temperature panel meter 7H2 代表 Temperature panel meter with 2 relays 7H3 代表 Temperature panel meter with 4 to 20 mA output
粤公网安备 44030402001379号