PX665-0.75BDI差压传感器 美国omega
DIN轨低差压变送器4-20 mA输出 px665系列 节省空间的紧凑型DIN导轨安装设计 低压差范围 板上电压调节允许使用成本低,不受管制的电力供应
规格
Excitation: 12 to 36 Vdc Output: 4 to 20 mA Accuracy: ±0.5% FS Non-Linearity: ±0.4% FS Hysteresis: ±0.02% FS Non-Repeatability: ±0.05% Warm-Up Time: 5 sec max to meet standard specifications from initial power-up Stability: ±0.5% FS / year Response Time: 250 ms Storage Temp.: -40 to 82°C (-40 to 180°F) Operating temp.: -28 to 82°C (-20 to 180°F) (10 to 95% RH non-condensing) Compensated Temp.: 2 to 57°C (35 to 135°F) Zero Temp. Effect: ±0.036% FS/°C (±0.02% FS/°F) Span Temp. Effect: ±0.036% FS/°C (±0.02% FS/°F) EMC: CE compliant to EN61326, 1997 ANNEX A harmonized heavy industrial transmitter specification Proof Pressure: 15 psid Burst Pressure: 25 psid Max Static Pressure: 25 psi Mounting Position Effect: 0.1% FS(<0.5" WC: 0.25% FS) Note: Mounting position effect easily corrected with zero potentiometer Zero and Span Potentiometers: Front accessible, non-interactive Zero: ±5% FS Span: ±3% FS Pressure Connections: 1/8 NPT female Weight: 127 grams (4.5 oz) Enclosure: Glass-filled polycarbonate (UL94 -V-1) Pressure Media: Clean, dry and non-corrosive gas NOT FOR USE WITH LIQUIDS Mounting: DIN rail types EN50022, 35 and 45 Models are also available with 1 to 5 mA output. Please see the PX663 for complete details, or contact our Pressure department for more information. 产品型号/产品描述 PX665-0.1DI DIN rail mountable differential pressure transducer with 0 to 0.1 inch of water range and 4 to 20 mA output PX665-0.25DI DIN rail mountable differential pressure transducer with 0 to 0.25 inch of water range and 4 to 20 mA output PX665-0.5DI DIN rail mountable differential pressure transducer with 0 to 0.5 inch of water range and 4 to 20 mA output PX665-0.75DI DIN rail mountable differential pressure transducer with 0 to 0.75 inch of water range and 4 to 20 mA output PX665-1DI DIN rail mountable differential pressure transducer with 0 to 1 inch of water range and 4 to 20 mA output PX665-1.5DI DIN rail mountable differential pressure transducer with 0 to 1.5 inch of water range and 4 to 20 mA output PX665-2DI DIN rail mountable differential pressure transducer with 0 to 2 inch of water range and 4 to 20 mA output PX665-2.5DI DIN rail mountable differential pressure transducer with 0 to 2.5 inch of water range and 4 to 20 mA output PX665-5DI DIN rail mountable differential pressure transducer with 0 to 5 inch of water range and 4 to 20 mA output PX665-10DI DIN rail mountable differential pressure transducer with 0 to 10 inch of water range and 4 to 20 mA output PX665-15DI DIN rail mountable differential pressure transducer with 0 to 15 inch of water range and 4 to 20 mA output PX665-20DI DIN rail mountable differential pressure transducer with 0 to 20 inch of water range and 4 to 20 mA output PX665-25DI DIN rail mountable differential pressure transducer with 0 to 25 inch of water range and 4 to 20 mA output PX665-50DI DIN rail mountable differential pressure transducer with 0 to 50 inch of water range and 4 to 20 mA output PX665-0.05BDI DIN rail mountable differential pressure transducer with -0.05 to +0.05 inch of water range and 4 to 20 mA output PX665-0.1BDI DIN rail mountable differential pressure transducer with -0.1 to +0.1 inch of water range and 4 to 20 mA output PX665-0.25BDI DIN rail mountable differential pressure transducer with -0.25 to +0.25 inch of water range and 4 to 20 mA output PX665-0.5BDI DIN rail mountable differential pressure transducer with -0.5 to +0.5 inch of water range and 4 to 20 mA output PX665-0.75BDI DIN rail mountable differential pressure transducer with -0.75 to +0.75 inch of water range and 4 to 20 mA output PX665-1BDI DIN rail mountable differential pressure transducer with -1 to +1 inch of water range and 4 to 20 mA output PX665-2.5BDI DIN rail mountable differential pressure transducer with -2.5 to +2.5 inch of water range and 4 to 20 mA output PX665-3BDI DIN rail mountable differential pressure transducer with -3 to +3 inch of water range and 4 to 20 mA output PX665-5BDI DIN rail mountable differential pressure transducer with -5 to +5 inch of water range and 4 to 20 mA output PX665-10BDI DIN rail mountable differential pressure transducer with -10 to +10 inch of water range and 4 to 20 mA output PX665-25BDI DIN rail mountable differential pressure transducer with -25 to +25 inch of water range and 4 to 20 mA output
粤公网安备 44030402001379号