model |
lf4-a |
appearance(㎜) |
48(w)×48(h)×75.5(d) |
terminal type |
8 pin socket |
control method |
up |
display method |
lcd |
display digit |
3 digits |
time setting range |
0.01s ~ 9990h |
counting input |
reset, start, inhibit |
input signal |
ㆍnon-voltage input ㆍclosing leakage voltage : max. 1v ㆍclosing impedance : max. 1㏁ ㆍoperating impedance : min. 100㏁ |
power voltage |
100 ~ 240vacㆍdc , 24 ~ 48vacㆍdc ( 50/60hz ) |
power consumption |
approx. 5va ( 220vac 60hz ) |
control output |
contact output : 1c 250vac 3a ( resistance load ) |
insulation resistance |
min. 100㏁ ( at 500vdc ) part of conduction terminal and exposured non-electrify metal part |
dielectric strength |
2,000vac 50/60hz for 1 minute ( between terminal ) |
vibration |
malfunction |
2 ~ 55hz, x,y,z each positions for 10 minutes |
durability |
10 ~ 55hz, 0.76㎜, x,y,z each positions for 2 hours |
shock |
malfunction |
100㎨ 6 positions each 3 times |
durability |
300㎨ 6 positions each 3 times |
life |
mechanical |
min. 10 millions operations ( relay type ) |
electrical |
min. 0.3 millons operations ( relay type ) |
ambient temperature and humidity |
0 ~ 50℃ ( 32 ~ 122℉ )ㆍ35 ~ 85%rh ( no icing ) |