item |
performance |
repetition error |
± 0.5% |
set error |
below ¡¾10% below ± 10% |
mechanical lifetime |
above 3,000,000 times |
return time |
below 100ms |
allowable voltage variation range |
rating voltage ± 10% |
voltage error |
below ± 0.2% |
ambient temperature |
-5 ~ +40 ℃ |
temperature error |
below ± 5% |
ambient humidity |
45 ~ 85% rh |
withstand voltage |
electric circuit earth |
ac2,000v/min |
between each circuits |
ac1,500v/min |
between contact gaps |
ac1,000v/min |
insulation resistance |
above 100 ㏁ |
withstand vibration |
16.7hz double amplitude 4.0mm |
withstand impact |
30g |
weight |
about 44g | | |
|
|
|
|
type |
operating contact pattern |
contact form |
rating conductive contact |
rating voltage |
consumption power |
control time range |
plug-intype |
st-m2 |
on-delay |
2a2b |
5a |
dc 12v dc 24v ac110v ac220v |
ac 110v 1.9va ac 200v2.1va dc 12v 0.9w dc 24v 1.1va |
0.1~3sec 0.5~6sec 1~12sec 2.5~30sec 5~60sec 7.5sec~3m 12sec~6m 12sec~12m 30sec~30m 30sec~60m |
st-m4 |
4a4b |
3a | |
|
|
|
|
|
|
type |
connection diagram |
operating pattern |
sm-m2 |
|
|
st-m4 |
|
| | |