Basic Specifications
Display Block | 10.4-inch TFT color LCD Effective screen area: 211.2 mm x 158.4 mm (640 dots x 480 dots) | |
Printer Block (RA1200/RA1300) | ||
Printing method | Thermal printing using a thermal head | |
Paper Width | 219.5 mm | |
Effective Recording Width | 1 split (200mmFS) to 16 splits (10mmFS), Number ofsplit and printing width can be changed. | |
Channel Discrimination | Prints channel number in the vicinity of theprinted waveform The ON/OFF function is available. | |
Battery Backup | Backup Contents: Main unit settings,Recording conditions Backup time: About 1 month (if fully charged and used under normaltemperature) | |
Storage Devices | A built-in 3.5-inch floppy disk drive(1.25MB/1.44MB) PC card slot (ATA flash memory card, SRAM card) Built-in MO unit (640, 540, 230, and 128MB supported): optional | |
Interface | RS-232C unit (38400 to 2400 bps): optional GP-IB unit (IEEE488 compliant): optional SCSI unit (50-pin type): optional | |
Remote Terminal | Start/stop, mark print, and paper feed areavailable by external signal, synchronous pulse Input, protect input, output of waveformjudgement results, and error output | |
Clock Function | Stability: Daily error within ±35 PPM (at normaltemperature) | |
Operating Environment | Temperature: 0 to 40°C (5 to 40°C whenFFD is operating) Humidity: 35 to 80% RH (without condensation) Vibration Resistance: MIL-STD-810E compliant (except when FD orMOis operating) | |
Power Supply | 90 to 132 VAC/180 to 264 VAC (to be specified whenordering) Frequency 47 to 63Hz DC power unit (optional) In use: 11 to 28 VDC(AC power isprioritized) | |
PowerConsumption(Maximum) | RA1100: Approx. 85 VA RA1200: Approx. 180 VA (About 85 VA during stand-by) RA1300: Approx. 350 VA (About 85 VA during stand-by) | |
Dimensions | Approx. 369.5 (W) x 150.5 (H) x 301(D)mm | |
Weight | Approx. 6.6kg (RA1100 main unit withfour 2-ch high-resolution DC amps) Approx. 7.5kg (RA1200 main unit with four 2-ch high-resolution DCamps) Approx. 7.5 kg (RA1300 main unit with four 2-ch high-resolution DCamps) |
Trigger Specifications
Trigger Mode | OR, AND, A*B, WINDOW | |||||||||
Trigger Source | Input Signal, time trigger (startingtime, ending time, measurement interval), manual trigger and external trigger | |||||||||
Trigger Setting | Amps other than event amps
| |||||||||
Event Amp
| ||||||||||
Trigger Related Functions | Pre-trigger , trigger pass count,trigger filter, and trigger mark |
Other Specifications
Print Functions(RA1200/RA1300) | ||
Data Information | Measurement mode, year/month/day,Measurement start time, Data No., Trigger conditions (Trigger point, Trigger year/month/day, Triggertime), Sampling speed, Chart speed, Time axis, etc. are printedsimultaneously with waveform print). ON/OFF function is available. | |
Channel Information | Input unit settings are printedsimultaneously. ON/OFF function is available. | |
Mark print | In the real-time mode, the mark printis available (M date/time) | |
List Print. | Date, time, measurement mode, data No., record form, chart speed, sampling speed, scale printing, back-light auto-off, auto start,buzzer click, trigger mode, source channel, recording operation, filingsetting printout | |
Screen Copy Function | Prints hard copies of the contentsshown on the screen | |
A4 report output | Registers free comments and prints themtogether with the waveform printing | |
Printing Line Width | Sets baseline boldness (1, 2, 3, 4dots) for each channel | |
Key Lock Function | Invalidates key input to preventerroneous operation | |
Storing and Readingof Settings | Up to four conditions for input unitand main unit settings are stored in the main unit memory | |
Physical ValueConversion | Physical conversion of input signal,full-scale modification of display | |
Stand-by Function | When the main unit is restored fromblackout or temporary halt, original state is regained.(Except when filing) | |
Automatic SetupFunction | By presetting a floppy disk containingthe measurement conditions in FD drive, the conditions are automatically read when turning on thepower. | |
Storing the ScreenImage | Stores a screen image in bitmap formatinto a floppy disk | |
Help Function | Displays the handling method, cautions,etc. | |
RS-232C Unit Function | ||
Remote Control | Controls the main unit from a personal computer viathe RS-232C cable. | |
FAX Transmission Function | Sends measured waveform by using a FAX modemconnected to RS-232C. | |
GB-IB Unit Function | ||
Remote Control | Controls the main unit from a personal computer viaGB-IB cable. | |
SCSI Unit Function | ||
Stores data to MO or PD as external memorydevices. |
AC Bridge Power Supply Unit (Optional)
Function | Bridge power source for 2-ch AC strainamp |
Power Voltage, Carrier Wave | 2 Vms, Sine wave 5kHz |
Synchronism | Synchronization with other RA1000susing a built-in AC bridge power unit is available. |
Memory Mode
Measurement Operation | Once, Repeat, Endless | |
Memory Capacity | 256kW/CH (Max.1 MW/CH optionallypossible) *When function operation is used, memory capacity is 1/4 When two channels are used, 2MW/CH is the maximum | |
Memory Division | 1, 2, 4, 8, 16, 32, 64, and 128divisions | |
Sampling | 1 µs (1 MS/s) to 1 s(1 S/s),User-settableExternal synchronization enabled | |
Display (ReplayMonitor) | ||
Waveform Display | Display magnification :x5 to x1/1000 | |
X-Y Display | X-Y display where data of an any channelis shown on the X axis, and other channel on the Y axis. Display step: 1 to 1000 steps | |
Print (RA1200/RA1300) | ||
Waveform Print | Print Density: Voltage axis: 8 dots/mmTime axis: 10 dots/mm Copy magnification: x5 to x1/1000 | |
Alphanumeric Print | Readout Interval : 1 to 1000 steps | |
X-Y Print | X–Y print where data of an any channelis shown on the X axis, and other channel on the Y axis. Effective print range : 200 mm x 200 mmPrint density : 400 dots (X axis) x 400 dots (Y axis) Display step : 1to 1000 steps | |
Memory Filing | Each time data is stored into memory,the data is saved in the memory device in the binary or CSV format. |
Real-Time Mode (RA1200/RA1300)
Waveform Printing | |||||||||||||
Measurement Starting Operation | Starts with the Start key, by thetrigger detection, or at set time. Interval recording available. | ||||||||||||
Paper Speed | 25 mm/s to 1 mm/sec (RA1200), 100 mm/sto 1 mm/min (RA1300), User settable. External synchronization enabled | ||||||||||||
Frequency Response | DC to 100 kHz (sampling points: 10points/cycle), Varies depending on the input units | ||||||||||||
Printing Density | Voltage axis : 8 dots/mm
| ||||||||||||
Printing Length | Continuous or 1 to 1000 division-shotfeeding | ||||||||||||
Alphanumeric Printing | |||||||||||||
Sampling | 1 s to 1 hour, User settable, Externalsynchronization enabled | ||||||||||||
Printing Length Setting | Continuous or 1 to 1000 data shot feeding | ||||||||||||
X-Y Printing | |||||||||||||
Performance | X-Y recording where data of an anychannel is shown on the X axis, and other channel on the Y axis. Continuous recording until stopbutton is pressed (pose function available) | ||||||||||||
Effective Printing Range | 200 mm x 200 mm | ||||||||||||
Printing Density | 400 dots (X axis) x 400 dots (Y axis) | ||||||||||||
Printing Speed | 10 ms or more | ||||||||||||
Backup Filing | Stores the measured data in a memorydevice in real-time Recording Speed: Synchronized with paper speed |
Transient Mode
Transient Recording(RA1200/RA1300) | ||
Function | Normally operates in the real-time mode.When trigger is detected, the mode is switched to the memory mode. | |
Real-time Section | In conformance with the waveformprinting in the real-time mode | |
Memory Section | In conformance with data storage andprinting in the memory mode | |
Transient Filing | ||
Function | Normally operates in backup filing, datais saved in a memory when trigger is detected, and when measurementfinishes, the memory data is saved. | |
Real-Time Section | In conformance with backup filing in the real-timemode | |
Memory Section | In conformance with memory filing in thememory mode |
Filing Mode
Data Recording | ||||||||||||||
Function | Stores the measured data real-time to amemory device (Real time filing) | |||||||||||||
Recording Speed | 200 µs to 60 s. Maximum recording speedvaries depending on number of channels and recording device. User settable Externalsynchronization ennobled | |||||||||||||
Recording Method | Select normal or ring Ring recording is possible (Repeated recording during set time) | |||||||||||||
Waveform Printing(RA1200/RA1300) | ||||||||||||||
Function | Prints the waveform of input signal | |||||||||||||
Paper Speed | 25 mm/s to 1 mm/m (RA1200), 100 mm/s to 1mm/m(RA1300) User Settable External synchronization enabled | |||||||||||||
Frequency Response | DC to 100 kHz (sampling point: 10points/cycle), Varies depending on the input units | |||||||||||||
Printing Density | Voltage axis : 8 dots/mm
|
FFT Unit (Optional)
1 Signal Analysis | Linear spectrum, power spectrum, RMS spectrum,power spectrum density, and octave analysis (1/1, 1/3) | |
2 Signals Analysis | Transfer function, coherence function,and cross-power spectrum | |
Window Function | Rectangular, hanning, hamming,exponential, force | |
Addition Processing | Simple additional average (time axis),simple additional average (frequency axis), exponential weighted average (frequency axis),and peak hold | |
Analysis Frequency | 400kHz, 200kHz, 80kHz, 40kHz, 20kHz,10kHz, 5kHz, 2kHz, 1kHz, 500Hz, 200Hz, 100Hz, 50Hz, 20Hz, and 10Hz | |
Resolution | 400 (1000), 800 (2000), 1600 (4000) Numbers in parentheses indicates the number of samplingpoints. |
Arithmetic Operation Unit (Optional)
Sectional StatisticalOperation | Maximum value, minimum value, P-P value, averagevalue, area, effective value, standard deviation, rising time,falling time | |
Function Operation | Four-function calculation, absolutevalue, differential, integration, secondary differential, doubleintegration, square root, exponential, common logarithm, movingaverage, and trigonometric functions (sin, cos,tan, asin, acos,atan) |
Waveform Judgment Unit (Optional)
Function | Measures waveform of input signals of eightchannels, and outputs the results of waveform judgement | |
Targets of OutputtingResults | Print on paper, FAX, data storage, orremote terminal output |
2-CH High Resolution Amp (AP11-101)
Input | 2channels/unit, isolated unbalanced input, isolatedBNC connector | |
Input coupling | AC and DC coupling | |
Input impedance | 1M![]() | |
Measurement range | 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, and 500 V | |
Range accuracy | Within 0.3% FS (Within 0.8% FS at 500V) | |
Offset accuracy | Within 0.3% FS (at 25°C) | |
Linearity | Within 0.1% FS | |
Allowable inputvoltage | Range of 10 V to 500 V: 500 V max. (ACor DC peak values) Range of 0.1 V to 5 V: 100 V max. (AC or DC peak values) | |
CMV | Unit only: 43 V (AC or DC peakvalues)When using isolated BNC cable (optional): 300 VAC | |
Frequency response | At DC coupling: DC to 50 kHz (+0.5, -3dB) At AC coupling: 0.3 to 50 kHz (+0.5, -3 dB) | |
Low-pass filter | Bessel type (attenuation factor: -12dB/OCT) 30, 300, 3 kHz, and OFF (+0.5, -3 dB) | |
A/D converter | 16 bits, 100 kHz max. (two channelsimultaneous sampling) | |
Temperature stability | Zero point: Within 0.03% FS/°C Gain (range): Within 0.01% FS/°C | |
Weight | 230 g |
2-CH High Speed Amp (AP11-103)
Input | 2channels/unit, isolated unbalanced input, isolatedBNC connector | |
Input coupling | AC and DC coupling | |
Input impedance | 1M![]() | |
Measurement range | 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, and 500 V | |
Range accuracy | Within 0.5% FS (Within 0.8% FS at 500V) | |
Offset accuracy | Within 0.5% FS (at 25°C) | |
Linearity | Within 0.2% FS | |
Allowable inputvoltage | Range of 10 V to 500 V: 500 V max. (ACor DC peak values) Range of 0.1 V to 5 V: 100 V max. (AC or DC peak values) | |
CMV | Unit only: 43 V (AC or DC peakvalues)When using isolated BNC cable (optional): 300 VAC | |
Frequency response | At DC coupling: DC to 400 kHz (+0.5, -3dB) At AC coupling: 0.3 to 400 kHz (+0.5, -3 dB) | |
Low-pass filter | Bessel type (attenuation factor: -12dB/OCT) 50, 500, 5 kHz, and OFF (+0.5, -3 dB) | |
A/D converter | 12 bits, 1 MHz max. (two channelsimultaneous sampling) | |
Temperature stability | Zero point: Within 0.03% FS/°C Gain (range): Within 0.01% FS/°C | |
Weight | 240 g |
2-CH TC/DC Amp (AP11-106)
Input | 2channels/unit, isolated unbalanced input, terminalblock 4 | |
Input coupling | DC coupling | |
Input impedance | 10M![]() | |
Thermocouple | R, T, J, K, and W | |
Measurement range | R: 0 to 1600°C T: -200 to 400°C J: -200 to 1000°C K: -200 to 1350°C W: 0 to 2300°C | |
Voltage measurementrange | 100, 200, 500 mV, 1, 2, 5, 10, 20 and50 V FS | |
Range accuracy | Temperature: Within 0.5% FS (Within 1%FS at 0°C or lower) Voltage: Within 0.5% FS | |
Cold junctioncompensation | Internal/external switchable Accuracy: Within 2°C (Within 1°C at stable temperature of 20°C atinput terminal) | |
Linearity | Within 0.1% FS | |
Allowable inputvoltage | 50 V (AC or DC peak values) | |
CMV | 43 V (AC or DC peak values) | |
Frequency response | DC to 40 kHz (+0.5, -3 dB) | |
Low-pass filter | Bessel type (attenuation factor: -18dB/OCT) 1, 30, 500, 5 kHz, and OFF (+0.5, -3 dB) | |
A/D converter | 15 bits, 100 kHz max. (two channelsimultaneous sampling) | |
Temperature stability | Accuracy: 0.04% FS/°C (When used astemperature amp) Zero point: Within 0.03% FS/°C (When used as DC amp) Gain (range): Within 0.01% FS/°C | |
Weight | 240 g |
TC/DC Amp (AP11-107)
Input | 1 channel/unit, isolated unbalanced input, 2binding posts | |
Input coupling | DC coupling | |
Input impedance | 10M![]() | |
Thermocouple | R, T, J, K | |
Measurement range | R: 0 to 800°C at 800°C FS and 0 to1600°C at 1600°C FS T: -200 to 200°C at 200°C FS and -200 to 400°C at 400°CFS J: -200 to 200°C at 200°C FS and -200 to 1000°C at 1000°C K: -200 to 200°C at 200°C FS and -200 to 1200°C at 1200°C | |
Voltage measurementrange | 10, 20, 50, 100, 200, 500 mV, 1, 2, 5,10, 20, and 50 V FS | |
Range accuracy | Temperature: Within 0.5% FS (Within 1%FS at 0°C or lower) Voltage: Within 0.5% FS | |
Linearity | Within 0.1% FS | |
Allowable inputvoltage | 50 V (AC or DC peak values) | |
CMV | 300V (AC or DC peak values) | |
Frequency response | DC to 40 kHz (+0.5, -3 dB) | |
Low-pass filter | Bessel type (attenuation factor: -18dB/OCT) 1, 30, 500, 5 kHz, and OFF (+0.5, -3 dB) | |
Reference junctioncompensation | Internal/external switchable | |
A/D converter | 14 bits, 100 kHz max. | |
Weight | 200 g |
Event Amp (AP11-105)
Number of channels | 8 channels/unit | |||||||||
Input signal | Sets voltage or contact for eachchannel Voltage input: Input voltage range 0 to +24 V
| |||||||||
Response time | 1µs or faster (Input level should be +5V or higher.) | |||||||||
Input connector | Round DIN connector 8P...2 pcs. Event amp side: XT2B-0800(Conformed to DIN45326) | |||||||||
Weight | 100 g |
2-CH AC Strain Amp (AP11-104)
Number of channels | 2 channels/unit, isolated balanced input, NDISconnector | |
Applicable gaugeresistance | 120![]() | |
Bridge power supply | Sine wave 2 Vrms, 5 kHz (Bridge powersupply is supplied separately.) | |
Gauge factor | 1.9 to 2.2 | |
Range of balance | Resistance: 2% (10000 µ![]() | |
Balance method | Resistance: Auto-balance Capacitance: Auto-balance (500 pF or lower, eliminatingconstantly) Balance time: Within 1s at 1 ch Within 0.5%Fs Remained voltageaccuracy | |
Maximum sensitivity | Over full-scale at 500 µ | |
Measurement range | 1, 2, 5, 10, 20 kµ![]() | |
Internal calibratorand accuracy | 0.5 k, 1 k, 2 k, 3 k, 5 kµ | |
Linearity | 0.2% FS | |
CMV | 300 VAC | |
Frequency response | DC to 2 kHz (+0.5, -3dB) | |
Low-pass filter | Butterworth type (attenuation factor:-12 dB/OCT) 10, 30 , 100, 300 Hz, and OFF (+0.5, -3 dB) | |
A/D converter | 16 bits, 100 kHz max. | |
Temperature stability | Zero point: Within 0.05% FS/°C Gain (range): Within 0.05% FS/°C | |
Weight | 285 g |
2-CH DC Strain Amp (AP11-110)
Number of channels | 2 channels/unit, isolated balancedinput, NDIS connector | |
Input coupling | DC | |
Input impedance | 10M![]() | |
Bridge power supply | 2 V and 5 V | |
Applicable gaugeresistance | 120 to 2 k ![]() | |
Gauge factor | 2 | |
Range of balance | 2% (15000 µ![]() | |
Balance method | Resistance: Auto-balance Balance time: 0.5 sec max. at 1ch Remained voltage accuracy: Within 0.3% FS | |
Measurement range | 2, 5, 10, 20, 50 kµ![]() 0.8, 2, 4, 8, 20 kµ ![]() | |
Voltage measurementrange | 2, 5, 10, 20, 50 mV FS | |
Range accuracy | Within 0.3% FS | |
Linearity | 0.1% FS | |
Allowable inputvoltage | 8 V (DC or AC peak values) | |
Frequency response | DC to 50 kHz (+0.5, -3dB) | |
Low-pass filter | Bessel type (attenuation factor: -12dB/OCT) 10, 30, 300 Hz, 1 kHz, and OFF (+0.5, -3 dB) | |
Temperature stability | Zero point: Within 0.1% FS/°C Gain (range): Within 0.01% FS/°C | |
CMV | 300 VAC | |
A/D converter | 16 bits, 100 kHz max | |
Weight | 240 g |
2-CH Vibration/RMS Amp (AP11-109)
Input | 2 channels/unit, isolated unbalancedinput, isolated BNC connector | |
Input coupling | AC and DC | |
Input impedance | 10 M![]() | |
Power supply forsensor | 2 mA, 18 V or higher | |
Measurement range | 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, 500 V | |
Range accuracy | DC amp range: Within 0.3% FS (Within0.8% FS at 500 V) RMS amp range: Within 2% FS (at DC and 40 Hz to 20 kHz) | |
Linearity | Within 0.1% FS | |
Crest factor | 2.8 max. (RMS amp) | |
CMV | Unit only: 42 V (DC or AC peakvalues) When isolated BNC cable (optional) is used: 300 V AC | |
Frequency response | DC coupling: DC to 50 kHz (+1, -3dB) AC coupling: 1 to 50 kHz (+1, -3 dB) | |
Low-pass filter | Butterworth type (attenuation factor:-24 dB/OCT) 30, 100, 300 Hz, 1 kHz, and OFF | |
High-pass filter | Butterworth type (attenuation factor:-24 dB/OCT) 10, 30, 100 Hz, and OFF | |
A/D converter | 16 bits, 100 kHz max. | |
Temperature stability | Zero point: Within 0.02% FS/°C Gain (range): Within 0.01% FS/°C | |
Weight | 270 g |
2-CH FFT Amp (AP11-102)
Input | 2 channels/unit, isolated unbalancedinput, isolated BNC connector | |
Input coupling | AC and DC (only AC coupling whenamp-embedded charge accelerometer is used) | |
Input impedance | 1 M![]() | |
Power supply forsensor | 2 mA, 18 V or higher | |
Measurement range | 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, 500 V | |
Range accuracy | Within 0.3% FS (Within 0.8% FS at 500V) | |
Linearity | Within 0.1% FS | |
Maximum input voltage | 500 V (DC or AC peak values) (30 V atAC coupling of 0.1 to 5 V) | |
CMV | Unit only: 42 V (DC or AC peakvalues) When isolated BNC cable (optional) is used: 300 V AC | |
Frequency response | DC coupling: DC to 50 kHz (+0.5, -3dB) AC coupling: 0.3 to 50 kHz (+0.5, -3 dB) | |
Low-pass filter | Bessel type (attenuation factor: -24dB/OCT) 30, 300 Hz, 3 kHz, and OFF (+0.5, -3 dB) | |
Anti-aliasing filter | 20, 40, 80, 200, 400, 800 Hz, 2, 4, 8,20, and 40 kHz Drop characteristic: -72 dB typ. at 1.5 x fc | |
Offset accuracy | Within 0.3% FS (at 25 °C) | |
A/D converter | 16 bits, 100 kHz max. | |
Temperature stability | Zero point: Within 0.02% FS/°C Gain (range): Within 0.01% FS/°C | |
Weight | 240 g |
F/V Converter (AP11-108)
Input | 1 channel/unit, isolated unbalancedinput, isolated BNC connector | |
Input coupling | AC and DC | |
Input impedance | 100 M![]() | |
Input frequency range | 1 Hz to 10 kHz (Pulse width: 20 µs orlonger) | |
Measurement range | 0.1, 0.2, 0.5, 1, 2, 5, 10 kHz FS | |
Range accuracy | Within 0.5% FS (Within 0.8% FS at 500V) | |
Linearity | Within 0.3% FS | |
Trigger level | Selectable from 0 V and 2.5 V | |
Allowable inputvoltage | 100 V (AC or DC peak values) | |
CMV | Unit only: 42 V (AC or DC peakvalues) Between isolated BNC and safety terminal (optional): 300 VAC | |
Response time | Approx. 20 ms (at the range of 10 kHz) | |
A/D converter | 16 bits, 100 kHz max. | |
Temperature stability | Zero point: Within 0.03% FS/°C Gain (range): Within 0.02% FS/°C | |
Weight | 240 g |
Charge Converter (AP11-901)
Gain | 1.0 mV/pC ±5% | |
Max. input charge | 5000 pC | |
Frequency range | Approx. 1.6 Hz to 50 kHz | |
Max. output voltage | 5 Vp-p or lower | |
Drive voltage | 12 to 25 VDC | |
Drive current | 0.5 to 5.0 mA | |
Rated noise | 20 µVrms or lower | |
Phase | 180°(Inverted input is output.) | |
Operating temperature | -20 to 80°C | |
Connector | Input: Miniature connector (10-32) Output: Male BNC terminal | |
Weight | 20 g |
Charge Converter (AP11-902)
Gain | 1.0 mV/pC ±5% | |
Max. input charge | 5000 pC | |
Frequency range | Approx. 1.6 Hz to 50 kHz | |
Max. output voltage | 5 Vp-p or lower | |
Drive voltage | 12 to 25 VDC | |
Drive current | 0.5 to 5.0 mA | |
Rated noise | 20 µVrms or lower | |
Phase | 180°(Inverted input is output.) | |
Operating temperature | -20 to 80°C | |
Connector | Input: Miniature connector (10-32) Output: Male BNC terminal | |
Weight | 65 g |
Charge Converter (AP11-903)
Gain | 1.0 mV/pC ±5% | |
Max. input charge | 50000 pC | |
Frequency range | Approx. 1.6 Hz to 50 kHz | |
Max. output voltage | 5 Vp-p or lower | |
Drive voltage | 12 to 25 VDC | |
Drive current | 0.5 to 5.0 mA | |
Rated noise | 20 µVrms or lower | |
Phase | 180°(Inverted input is output.) | |
Operating temperature | -20 to 80°C | |
Connector | Input: Miniature connector (10-32) Output: Male BNC terminal | |
Weight | 65 g |
Name | Model | Rating | |
Main unit | Omniace II | RA1100 | Data acquisition system without printer |
RA1200 | Data acquisition system with printer, paper speed:25 mm/s max. | ||
RA1300 | Data acquisition system with printer, paper speed:100 mm/s max. |
Standard accessories | AC power cable x 1, Recording paper x 1(RA1200/1300), Paper holder x 1 (RA1200/1300), Slot cover plate forinput and interface units x 1 set, and user's manual x 1set |