Input Voltage: | 10~30VDC with normal line at +24VDC |
Input Frequency: | 47~63Hz |
Input Current: | 13A at 10VDC max. |
Inrush Current: | < 15A at 10VDC input from cold start excluding EMI capactiors |
Load Range: | With all other outputs within their specified voltage accuracy ranges and 60% rated load conditions, the +5V output is between 5~5.1V. It could last 10 sec. at peak load and 25°C |
Ripple and Noise: | Peak to peak ripple and noise for +5V is < 50mV, and < 100mV for the other |
Line Regulation: | < +/-2% for each output at rated load and < +/-10% +12V and +24V input variables |
Load Regulation: | < +/-1% for +5V, < +/-5% for +12V and -12V |
Efficiency: | > 70% at nominal line and rated load |
Altitude: | > 10,000 feet |
Protection: | Built-in over voltage protection circuit. Trip point of crowbar circuit is between 5.7~7V hiccup mode against short circuit or over load conditions auto recovery when fault conditions are removed O.C.P. of +5V is 20A max. |
Temperature: | 0~+50°C (operating); -40~+85°C (storage) |
Connectors: | DC Input: Terminal blocks DC Output: Molex 5273-04A or equivalent device For Fan Use Only: Molex 5045-02A or equivalent device |
Dimensions: | 12.7 x 7.62 x 3.86 cm at tolerance +/-0.4mm |