TPS2000 Series Oscilloscopes Deliver Powerful Productivity from Bench to FieldAs an engineer or technician, you must often make floating, or differential, measurements. You face faster edges and clocks due to the migration of higher performance technologies to widely implemented electronic systems and subsystems, with the pressure to conform to customer specifications or industry requirements. And you may need to develop and test designs in a variety of challenging environments that demand versatility. You can quickly tackle these tough challenges to speed the design, troubleshooting, installation, and maintenance of components and systems with the world's first 4-isolated-channel, full featured, battery-powered oscilloscope – the TPS2000 Series. Make Floating and Differential Measurements – Quickly, Accurately, AffordablyMake floating and differential measurements much more quickly and accurately, and speed verification of power supply performance, complex control circuits and the effects of neutral current for differential voltages, up to 30 VRMS floating on four channels simultaneously, when the TPS2000 Series is paired with its standard P2220 passive probe. Easily perform these measurements up to 600 VRMS CAT II (or 300 VRMS CAT III) floating when the oscilloscope is coupled with its optional P5120 passive, high-voltage probe. Accurately characterize rise and fall times and other waveform parameters in circuits with different low levels or ground references, while removing ground loop interference, with just 37 pf capacitance to chassis on each of four isolated channels. Innovative IsolatedChannel™ technology makes these measurements possible - all designed with your safety in mind. Four IsolatedChannel™ inputs and isolated external trigger input for quick, accurate, affordable floating and differential measurements. Speed the Design and Test of Industrial Power Systems and SubsystemsThe TPS2000 Series easily addresses the unique challenges that plague industrial power designers and technicians. You regularly confront high voltages and currents, and must often make potentially hazardous floating measurements. With the TPS2000 Series' power bundle (TPS2PBND), which includes the P5120 passive, high-voltage probes and TPS2PWR1 power measurement and analysis software, you can use a single instrument to make a broad range of measurements. Easily evaluate these high voltages and currents, or debug power electronics control circuits, with differential voltages up to 600 VRMS CAT II (or 300 VRMS CAT III) floating. Accurately measure three-phase power and circuits with different low levels or ground references. Quickly perform a broad range of power-specific measurements, such as switching loss, harmonic distortion measurements to the 50th harmonic, and dv/dt and di/dt cursor measurements. Perform three-phase power measurements of variable frequency drives. Conduct harmonic distortion measurements with TPS2PWR1 software. Quickly Debug and Characterize Signals with DRT Sampling TechnologyCharacterize a wide range of signal types on four channels simultaneously with the TPS2000 Series’ unique digital real-time (DRT) sampling technology. This acquisition technology makes it possible to capture high-frequency information, such as glitches and edge anomalies, that eludes other oscilloscopes in its class, so that you can be sure to get a complete view of your signal to speed debug and characterization. Capture elusive glitches - the first time - with digital real-time (DRT) sampling technology. Easily Analyze and Document Your Measurement ResultsQuickly reveal signal interference, cross-talk and the effects of vibration with frequency domain analysis using the TPS2000 Series' standard Fast Fourier Transform (FFT) feature. Easily analyze and document your measurement results with integrated CompactFlash® mass storage or OpenChoice® software. Correlate Your Measurements from Bench to Lab to Field*1Use the TPS2000 Series on your bench, in the lab, or in the field, with the industry’s longest continuous battery life – 8 hours and beyond – in a highly mobile package. Harness the power of virtually unlimited freedom from an AC power source with hot-swappable batteries. Easily correlate measurements between bench, lab, and field with its portability. Easily correlate your measurements between bench, lab, and field with the TPS2000 Series' portability. *1 Please refer to Environmental and Safety specifications. Optimize Your Productivity with VersatilityIntuitively operate the oscilloscope with familiar, analog-style knobs per channel. Reduce your measurement time with features like autoset, autorange, automatic measurements, 10X to 1000X vertical position control, probe check wizard, and context-sensitive help. Effectively work in a variety of challenging environments – from bright daylight to dimly lit areas – using backlit menu buttons and brightness/contrast controls. Harness the power of virtually unlimited freedom from an AC power source with hot-swappable batteries. Easily use the oscilloscope even in environments that challenge operation, with features such as analog-style knobs per channel, backlit menu buttons, and brightness/contrast controls. Speed documentation and analysis of measurements results with OpenChoice® software and integrated CompactFlash® mass storage. CharacteristicsTPS2000 Series Electrical CharacteristicsFeature | TPS2012 | TPS2014 | TPS2024 |
---|
Isolated Channels | 2 | 4 | 4 | Bandwidth*1 (MHz) | 100 | 100 | 200 | Sample Rate (GS/s) per channel | 1.0 | 1.0 | 2.0 | Record Length | 2.5 K points | Display (1/4 VGA LCD) | Color | Battery Operation | Capacity for two hot-swappable battery packs. One standard battery pack offers 4 hours of battery operation. Optional second battery pack extends battery operation to 8 hours. Continuous battery operation is possible by hot-swapping charged batteries. | Automatic Measurements | 11 | Isolated External Trigger Input (Impedance Isolated) | Yes | Vertical Resolution | 8-bits (normal or with averaging) | Vertical Sensitivity | 2 mV to 5 V/div on all models with calibrated fine adjustment | DC Vertical Accuracy | ±3% | Vertical Zoom | Vertically expand or compress a live or stopped waveform | Max Input Voltage (1 MΩ)*2 | 300 VRMS CAT II at BNC signal to BNC shell, 1000 VRMS CAT II at probe tip to earth ground with optional P5120 passive, high-voltage probe | Float Voltage*2 | 600 VRMS CAT II or 300 VRMS CAT III BNC shell to earth ground, 1200 VRMS CAT II between any two channel commons with each of the channel commons not being more than +/- 600 VRMS from earth ground | Position Range | 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V | Bandwidth Limit | 20 MHz | Linear Dynamic Range | ±5 div | Time Base Range | 5 ns to 50 s/div | 5 ns to 50 s/div | 2.5 ns to 50 s/div | Time Base Accuracy | 50 ppm | Input Impedance | 1 MΩ ±2 % in parallel with 20 pF | Input Coupling | AC, DC, GND | Horizontal Zoom | Horizontally expand or compress a live or stopped waveform | FFT | Standard | RS-232, Centronics-Parallel Ports | Standard | PC Connectivity | Standard | Integrated CompactFlash® Mass Storage | Standard | Power Measurements | Optional package that offers instantaneous power waveform analysis, waveform analysis, harmonics analysis, switching loss, phase angles, dv/dt and di/dt cursors |
*1 Bandwidth is 20 MHz at 2 mV/div, all models. Bandwidth is 200 MHz typical at 5 mV/div, 200 MHz models only. Bandwidth is 200 MHz typical between 40 °C and 50 °C, 200 MHz models only. *2 Please refer to Environmental and Safety specifications. Acquisition ModesPeak Detect - High frequency and random glitch capture. Captures glitches as narrow as 12 ns typical using acquisition hardware at all time/div settings from 5 μs/div to 50 s/div. Sample - Sample data only. Average - Waveform averaged, selectable: 4, 16, 64, 128. Single Sequence - Use the Single Sequence button to capture a single triggered acquisition sequence at a time. Scan/Roll Mode - At acquisition time base settings of ≥100ms/div . Trigger System (Main Only)Trigger Modes - Auto, Normal, Single Sequence. Trigger TypesEdge (rising or falling) - Conventional level-driven trigger. Positive or negative slope on any input. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject. Video - Trigger on all lines or individual line, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM). Pulse Width (or Glitch) - Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 sec. Trigger Source2-channel model - CH1, CH2, Ext, Ext/5, Ext/10. 4-channel models - CH1, CH2, CH3, CH4, Ext, Ext/5, Ext/10. Trigger ViewDisplays trigger signal while trigger view button is depressed. Trigger Signal Frequency ReadoutProvides a frequency readout of the trigger source with 6-digit resolution. CursorsTypes - Voltage, Time. Measurements - ΔT, 1/ΔT (frequency), ΔV, dv/dt*3, di/dt*3. *3 Requires TPS2PWR1 power application package. Measurement SystemAutomatic Waveform Measurements - Period, Frequency, +Width, –Width, Rise time, Fall time, Max, Min, Peak-to-Peak, Mean, Cycle RMS. Waveform ProcessingOperators - Add, Subtract, Multiply, FFT. FFT - Windows: Hanning, Flat Top, Rectangular; 2048 sample points. Sources - 2-channel models: CH1 - CH2, CH2 - CH1, CH1 + CH2, CH1 × CH2. 4-channel models: CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4. Autoset Menu - Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset. Autorange - Allows the user to change test points without resetting the oscilloscope. Autoset Menu for Multiple Signal TypesSignal Type | Autoset Menu Choices |
---|
Square wave | Single-cycle, Multi-cycle, Rising or Falling Edge | Sine Wave | Single-cycle, Multi-cycle, FFT Spectrum | Video (NTSC, PAL, SECAM) | Video (NTSC, PAL, SECAM) Field: All, Odd, or Even Line: All or Selectable Line Number |
Nonvolatile StorageNonvolatile Storage | Standard (with CompactFlash® Mass Storage) | Reference Waveform Display | Two 2500 point reference waveforms | Waveform Storage | 96 or more reference waveforms per 8 MB | Setups | 4000 or more front panel setups per 8 MB | Screen Images | 128 or more screen images per 8 MB (the number of images depends on file format selected) | Save All | 12 or more Save All operations per 8 MB. A single Save All operation creates 2 to 9 files (setup, image, plus one file for each displayed waveform). |
Display CharacteristicsDisplay - 1/4 VGA, passive color LCD with color on black background with adjustable multi-level contrast and brightness controls. Interpolation - Sin(x)/x. Display Types - Dots, vectors. Persistence - Off, 1 sec, 2 sec, 5 sec, infinite. Format - YT and XY. I/O InterfacePrinter Port (standard) - Centronics-type Parallel. Graphics File Formats – TIFF, PCX (PC Paint Brush), BMP (Microsoft Windows), EPS (Encapsulated Postscript) and RLE. Printer Formats – Bubble Jet, DPU-411, DPU-412, DPU-3445, Thinkjet, Deskjet, Laser Jet, Epson Dot (9- or 24-pin), Epson C60, Epson C80. Layout – Landscape and Portrait. RS-232 Port (standard) - 9-pin DTE. RS-232 Programmability - Full talk/listen modes. Control of all modes, settings and measurements. Baud rate up to 19,200. Mass Storage CompactFlash® Memory - • Accepts any Type 1 CompactFlash® card, up to and including 1 GB (card not included). Built-in Clock/Calendar OpenChoice PC Communications Software - • Seamless connection from oscilloscope to PC through RS-232. • Transfer and save settings, waveforms, measurements, and screen images. • Includes a Windows desktop data transfer application in addition to convenient Microsoft Word and Excel Toolbar Add-ins. Environmental and SafetyTemperature - Operating: 0 °C to +50 °C. Non-operating: -40 °C to +71 °C. Humidity - TPS2000 Series oscilloscopes are not intended for use in wet or damp conditions. Operating: high: 50 °C / 60% RH. low: 30 °C / 90% RH. Non-Operating: high: 55 °C to 71 °C / 60% RH max wet bulb. low: 30 °C to 0 °C / < 90% RH max wet bulb. Altitude - Operating: up to 3,000 m. Non-operating: 15,000 m. Pollution Degree 2 - Do not operate in an environment where conductive pollutants may be present (as defined in IEC61010-1:2001). Enclosure Rating - IP30: when the CompactFlash® card and power analysis software are installed (as defined in IEC60529:2001) Electromagnetic Compatibility - Meets the intent of Directive 89/336/EEC. Meets or exceeds: Australian EMC Framework, demonstrated per Emission Standard AS/NZS 2064.1/2. General Certifications - Russian GOST EMC regulations. Safety - UL61010-1: 2004. CAN/CSA22.2 *****010.1: 2004. EN61010-1: 2001. Do not float the P2220 probe common lead to >30 VRMS. Use the P5120 (floatable to 600 VRMS CAT II or 300 VRMS CAT III) or similarly rated passive, high-voltage probe or an appropriately rated high-voltage, differential probe when floating the common lead above 30 VRMS, subject to the ratings of such high-voltage probe. CAT Ratings Overvoltage Categories Category | Examples of Products in this Category |
---|
CAT III | Distribution-level mains, fixed installation | CAT II | Local-level mains, appliances, portable equipment | CAT I | Signal levels in special equipment or parts of equipment, telecommunications, electronics |
Materials - TPSBAT battery contains less than 8 grams equivalent Lithium. Physical CharacteristicsINSTRUMENT |
---|
Dimensions | mm | in. |
---|
Weight | kg | lbs. |
---|
INSTRUMENT SHIPPING |
---|
Package Dimensions | mm | in. |
---|
Width | 336.0 | 13.24 | Height | 161.0 | 6.33 | Depth | 130.0 | 5.10 | Instrument only | 2.7 | 6.0 | with 1 battery | 3.2 | 7.0 | with 2 batteries | 3.7 | 8.0 | Width | 476.2 | 18.75 | Height | 266.7 | 10.50 | Depth | 228.6 | 9.00 |
Ordering InformationTPS2012, TPS2014, TPS2024Digital Storage Oscilloscopes Standard Accessories Probes - P2220 200 MHz, 1X/10X switchable passive probe (one per channel). Battery (1) - Lithium-Ion battery with fuel gauge for 4-hour battery life. Two batteries required for 8 hours continuous battery operation. TDSPCS1 OpenChoice PC Connectivity Software - A collection of programs that enable fast and easy communication between MS Windows PCs and TPS2000 Series oscilloscopes. Documentation - 1 each set of instruction manuals (see below for the appropriate language manual part number.) AC Adapter with Power Cord. NIM/NIST-Traceable Certificate of Calibration. Front Protective Cover. Battery/charger. Versatile hanger. P5120 Probe. Recommended Accessories TPS2PBND - Power bundle for TPS2000 Series oscilloscopes. Includes (4) P5120 passive, high-voltage probes and TPS2PWR1 power measurement and analysis software. TPS2PWR1 - Power measurements application package. Instantaneous power waveform analysis, waveform analysis, harmonics analysis, switching loss, phase angles, dv/dt and di/dt cursors. WSTRO - WaveStar software; Windows 98/2000/ME/NT 4.0 application for waveform capture, analysis, documentation and control from your PC. Provides enhanced oscilloscope data measurement, analysis, remote setup and charting features. TPSBAT - Additional battery. TPSCHG - Battery charger. AC2100 - Soft case for carrying instrument. HCTEK321 - Hard case for carrying instrument. 343-1689-00 - Versatile hanger. Service Manual - English only (P/N 071-1465-xx). Programmer Manual - English only (P/N 071-1075-xx). 156-9413-00 - CompactFlash® memory card, 32 MB or more. Recommended Probes A621 - 2000 A, 5-50 kHz AC current probe/BNC. A622 - 100 A, 100 kHz AC/DC current probe/BNC. P5120 - Passive high-voltage probe (1000 V CAT II tip to ground; 600 V CAT II reference to earth ground). P5205 - High-voltage active differential probe (1300 Vpk-pk, 100 MHz). (1103 power supply required). P5210 - High-voltage active differential probe (5600 Vpk-pk, 50 MHz). (1103 power supply required). CT2 - 2.5 A, 200 MHz AC current probe. CT4 - AC current probe up to 2000 A pk-pk. (TCP202 and 1103 power supply required.) TCP202 - 15 A, 50 MHz AC/DC current probe. (1103 power supply required.) TCP303/TCPA300 - 150 A, 15 MHz AC/DC current probe/amplifier. TCP305/TCPA300 - 50 A, 50 MHz AC/DC current probe/amplifier. TCP312/TCPA300 - 30A, 100 MHz, DC/AC current probe/amplifier. TCP404XL/TCPA400 - 500 A, 2 MHz AC/DC current probe/amplifier. Soft carrying case. P2220 Probe. Current Probes. International Power Plugs Opt. A0 - North America power. Opt. A1 - Universal EURO power. Opt. A2 - United Kingdom power. Opt. A3 - Australia power. Opt. A5 - Switzerland power. Opt. A6 - Japan power. Opt. A10 - China power. Opt. A99 - No power cord or AC adapter. Accessory Cables RS-232, 9-Pin female to 25-Pin male, 4.6 m (15 ft.), for Modems - Order 012-1241-00. RS-232, 9-Pin female to 9-Pin female, null modem, for computers - Order 012-1651-00. RS-232, 9-Pin female to 25-Pin female, null modem, for computers - Order 012-1380-00. RS-232, 9-Pin female to 25-Pin male, null modem, for printers - Order 012-1298-00. Centronics, 25-Pin male to 36-Pin Centronics, 2.4 m (8 ft.), for Parallel Printer Interfaces - Order 012-1214-00. International User Manual Language Options Opt. L0 - English (071-1441-xx). Opt. L1 - French (071-1442-xx). Opt. L2 - Italian (071-1443-xx). Opt. L3 - German (071-1444-xx). Opt. L4 - Spanish (071-1445-xx). Opt. L5 - Japanese (071-1446-xx). Opt. L6 - Portuguese (071-1447-xx). Opt. L7 - Simplified Chinese (071-1448-xx). Opt. L8 - Traditional Chinese (071-1449-xx). Opt. L9 - Korean (071-1450-xx). Opt. 10 - Russian (071-1451-xx) Translated front panel overlay included with its respective user manual. Warranty Information Three year warranty covering all labor and parts, excluding probes and accessories. Speed Product Development with Best-in-class Price/Performance. Tektronix' extensive portfolio of proven, state-of-the-art stimulus, probing, acquisition and analysis tools simplify and speed each phase of product design - from power-on and verification, through debug and validation, to characterization and test - to enable you to race products to your customers when they need them, if not before. - Tektronix Support Completes the Solution. Anytime you need support, anywhere in the world, depend on Tektronix Support to give you the lowest possible exposure to inconvenience, delay, or disruption of operations. www.tektronix.com/support.
- Unsurpassed technical expertise and experience with 24-hour response to technical questions
- Industry-leading, turn-around service time
- 90-day unconditional service warranty
- No fine print, no exclusions, no surprises
- Global support in more than 50 countries
3MW-17750-4, 06-AUG-2007 |