TDS2000B Series Oscilloscopes
Instantly Productive. Incredibly Easy.
The TDS1000B and TDS2000B Series digital storage oscilloscopes deliver
an unbeatable combination of performance and ease-of-use, at a price you can afford.
Affordable Digital Precision
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other color digital storage oscilloscope
offers as much bandwidth and sample rate for the price. The TDS1000B and TDS2000B Series oscilloscopes
provide accurate real-time acquisition up to their full bandwidth, the same record length at all time base settings,
advanced triggers to isolate signals of interest, and 11 standard automatic measurements on all models.
Their Fast Fourier Transform (FFT) and waveform add, subtract, and multiply math functions allow you to analyze,
characterize, and troubleshoot circuits.
Quick and Easy Waveform Capture
The simple user interface with classic analog-style controls makes these instruments easy to use,
reducing learning time and increasing efficiency. Innovative features such as the Autoset Menu,
Probe Check Wizard, Context-Sensitive Help Menu and color LCD display (TDS2000B Series)
optimize instrument setup and operation.
Flexible Data Transfer
With USB host and device ports which enable removable data storage, seamless PC connectivity,
and direct printing, no other color or monochrome digital storage oscilloscope offers as much flexibility
and ease of data transfer for the price.
Simple Documentation and Analysis
Easily capture, save and analyze measurement results with OpenChoice PC Communications Software.
Simply pull screen images and waveform data into the stand-alone desktop application or directly into
Microsoft Word and Excel. To complement OpenChoice, National Instruments SignalExpress Tektronix
Edition Software provides you with extended capabilities, including advanced analysis, remote oscilloscope
control and live waveform analysis. Alternatively, if you prefer not to use the PC, you can simply print your
image directly to any PictBridge compatible printer via the USB device port.
Performance You Can Count On
Depend on Tektronix to provide you with performance you can count on. In addition to industry leading
service and support, every TDS1000B and TDS2000B Series oscilloscope comes backed with a Lifetime
Warranty*1 as standard.
Quickly and easily capture waveforms Conveniently use your USB flash drive to store screen shots and waveform data Easily capture, save and analyze measurement results with OpenChoice PC Communications Software Characteristics
TDS1000B and TDS2000B Series Digital Storage Oscilloscopes
| TDS1001B | TDS1002B | TDS1012B | TDS2002B | TDS2004B | TDS2012B | TDS2014B | TDS2022B | TDS2024B |
---|
I/O INTERFACES |
---|
NON-VOLATILE STORAGE |
---|
Display (1/4 VGA LCD) | Mono | Mono | Mono | Color | Color | Color | Color | Color | Color |
Bandwidth*2 | 40 MHz | 60 MHz | 100 MHz | 60 MHz | 60 MHz | 100 MHz | 100 MHz | 200 MHz | 200 MHz |
Channels | 2 | 2 | 2 | 2 | 4 | 2 | 4 | 2 | 4 |
External Trigger Input | Included on all models |
Sample Rate on each channel | 500 MS/s | 1.0 GS/s | 1.0 GS/s | 1.0 GS/s | 1.0 GS/s | 1.0 GS/s | 1.0 GS/s | 2.0 GS/s | 2.0 GS/s |
Record Length | 2.5 K points at all time-bases on all models |
Vertical Resolution | 8 bits |
Vertical Sensitivity | 2 mV to 5 V/div on all models with calibrated fine adjustment |
DC Vertical Accuracy | +3% on all models |
Vertical Zoom | Vertically expand or compress a live or stopped waveform |
Maximum Input Voltage | 300VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13Vpk-pk AC at 3 MHz |
Position Range | 2 mV to 200 mV/div +2 V; >200 mV to 5 V/div +50 V |
Bandwidth Limit | 20 MHz for all models |
Input Coupling | AC, DC, GND on all models |
Input Impedance | 1 MΩ in parallel with 20pF |
Time Base Range | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 5 ns to 50 sec/div | 2.5 ns to 50 sec/div | 2.5 ns to 50 sec/div |
Time Base Accuracy | 50 ppm |
Horizontal Zoom | Horizontally expand or compress a live or stopped waveform |
USB Ports | Included on all models: 2 USB 2.0 Ports USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge compatible printers |
GPIB | Optional |
Reference Waveform Display | (2) 2.5 K point reference waveforms |
Waveform Storage w/o USB Flash Drive | (2) 2.5 K point | (2) 2.5 K point | (2) 2.5 K point | (2) 2.5 K point | (4) 2.5 K point | (2) 2.5 K point | (4) 2.5 K point | (2) 2.5 K point | (4) 2.5 K point |
Waveform Storage with USB Flash Drive | 96 or more reference waveforms per 8 MB |
Setups w/o USB Flash Drive | 10 front panel setups |
Setups with USB Flash Drive | 4000 or more front panel setups per 8 MB |
Screen Images with USB Flash Drive | 128 or more screen images per 8 MB (the number of images depends on file format selected) |
Save All with USB Flash Drive | 12 or more Save All operations per 8 MB. A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) |
*2 Bandwidth is 20 MHz at 2 mV/div, all models
Acquisition Modes
Peak Detect - High frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) using acquisition hardware at all time base settings from 5 μs/div to 50 s/div.
Sample - Sample data only.
Average - Waveform averaged, selectable: 4, 16, 64, 128.
Single Sequence - Use the Single Sequence button to capture a single triggered acquisition sequence at a time.
Roll Mode - At acquisition time base settings of >100 ms/div.
Trigger System
Trigger Modes - Auto, Normal, Single Sequence.
Trigger Types
Edge (rising / falling) - Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject.
Video - Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM).
Pulse Width (or Glitch) - Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s.
Trigger Source
2-channel models - CH1, CH2, Ext, Ext/5, AC Line.
4-channel models - CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line.
Trigger View
Displays trigger signal while trigger view button is depressed.
Trigger Signal Frequency Readout
Provides a frequency readout of the trigger source.
Cursors
Types - Amplitude, Time.
Measurements - [Δ]T, 1[Δ]T (frequency), [Δ]V.
Automatic Waveform Measurements
Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS.
Waveform Math
Operators -
Add, Subtract, Multiply, FFT.
FFT -
Windows, Hanning, Flat Top, Rectangular, 2048 sample points.
Sources -
2-channel models: CH1 - CH2, CH2 - CH1, CH1+CH2, CH1xCH2
4-channel models: CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4, CH1 x CH2, CH3 x CH4
Autoset Menu
Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset.
Signal Type | Autoset Menu Choices |
---|
Square Wave | Single-cycle, Multi-cycle, Rising or Falling Edge |
Sine Wave | Single-cycle, Multi-cycle, FFT Spectrum |
Video (NTSC, PAL, SECAM) | Field: All, Odd or Even Line: All or Selectable Line Number |
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes.
Display Characteristics
Display -
Color models: ¼ VGA passive color LCD with color on black background with adjustable multi-level contrast.
Monochrome models: ¼ VGA backlit passive LDC with adjustable multi-level contrast and inverse video selectable from front panel.
Interpolation -
Sin(x)/x.
Display Types -
Dots, vectors.
Persistence -
Off, 1 s, 2 s, 5 s, infinite.
Format -
YT and XY.
Environmental and Safety
Temperature - Operating: 0 ºC to +50 ºC.
Non-operating: -40 ºC to +71 ºC.
Humidity - Operating and Non-operating: up to 80% RH at or below +40 ºC. Operating and Non-operating: up to 45% RH up to +50 ºC.
Altitude - Operating and Non-operating: up to 3,000 m.
Electromagnetic Compatibility - Meets Directive 89/336/EEC, amended by 93/68/EEC, meets or exceed EN55011 Class A Radiated and Conducted Emissions; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC Framework, demonstrated per Emission Standard AS/NZS 2064; Russian GOST EMC regulations.
Safety - UL610100-1:2003, CSA22.2 No. 61010-1:2003, EN61010-1:2001, IEC61010-1:2001.
Physical Characteristics
Instrument |
---|
Dimensions | mm | in. |
---|
Weight | kg | lbs. |
---|
Package Dimensions | mm | in. |
---|
RM2000B Rackmount | mm | in. |
---|
Width | 326.3 | 12.85 |
Height | 158.0 | 6.22 |
Depth | 124.2 | 4.89 |
Instrument only | 2.0 | 4.4 |
with accessories | 2.2 | 4.9 |
Instrument Shipping |
Width | 476.2 | 18.75 |
Height | 266.7 | 10.5 |
Depth | 228.6 | 9.0 |
Width | 482.6 | 19.0 |
Height | 177.8 | 7.0 |
Depth | 108.0 | 4.25 |
Ordering Information
TDS1001B: 40 MHz, 2 Ch, 500 MS/s, Monochrome DSO.
TDS1002B: 60 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS1012B: 100 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS2002B: 60 MHz, 2 Ch , 1 GS/s, Color DSO.
TDS2004B: 60 MHz, 4 Ch , 1 GS/s, Color DSO.
TDS2012B: 100 MHz, 2 Ch, 1 GS/s, Color DSO.
TDS2014B: 100 MHz, 4 Ch, 1 GS/s, Color DSO.
TDS2022B: 200 MHz, 2 Ch, 2 GS/s, Color DSO.
TDS2024B: 200 MHz, 4 Ch, 2 GS/s, Color DSO.
Standard Accessories
P2220 - 200 MHz 10x - 1x Switchable Passive Probes (one per channel).
Power Cord - (Please specify plug option).
NIM/NIST - Traceable Certificate of Calibration.
Documentation - User Manual (Please specify preferred language option).
OpenChoice PC Communications Software - Enables fast and easy communication between a Windows PC and the TDS1000B and TDS2000B Series via USB. Transfer and save settings, waveforms, measurements and screen images.
National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Base Version - A fully interactive measurement software environment optimized for the TDS1000B and TDS2000B Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using intuitive drag-and-drop user interface that does not require any programming. Standard TDS1000B and TDS2000B Series support for acquiring, controlling, viewing and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing and user-defined step capabilities. Order SIGEXPTE for permanent Professional Version capability.
Limited Lifetime Warranty *3 covering labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories*4.
*3 Lifetime is defined as five years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least ten years from date of original purchase. Lifetime warranty is non-transferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty.
International Power Plugs
Opt. A0 - North America power.
Opt. A1 - Universal EURO power.
Opt. A2 - United Kingdom power.
Opt. A3 - Australia power.
Opt. A5 - Switzerland power.
Opt. A6 - Japan power.
Opt. A10 - China power.
Opt. A11 - India power.
Opt. A99 - No power cord or AC adapter.
User Manual Options
Opt. L0 - English manual.
Opt. L1 - French manual.
Opt. L2 - Italian manual.
Opt. L3 - German manual.
Opt. L4 - Spanish manual.
Opt. L5 - Japanese manual.
Opt. L6 - Portuguese manual.
Opt. L7 - Simple Chinese manual.
Opt. L8 - Standard Chinese manual.
Opt. L9 - Korean manual.
Opt. L10 - Russian manual.
Translated front panel overlays included with their respective user manuals.
Recommended Accessories
TEK-USB-488 - GPIB to USB converter.
SIGEXPTE - National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Professional Version.
AC2100 - Soft Carrying Case for Instrument.
HCTEK4321 - Hard Plastic Carrying Case for Instrument (requires AC2100).
RM2000B - Rack Mount Kit.
071-1075-xx - Programmer Manual - English Only.
071-1828-xx - Service Manual - English Only.
TNGTDS01 - Operator Training Kit - Extensive instructions and step-by-step lab exercises provide education about the operation of TDS1000B and TDS2000B Series oscilloscopes. Kit includes self-paced CD-ROM based manual and signal source board.
174-4401-00 - USB host to device cable, 3 feet long.
Recommended Probes
P2220 - 10X to 1X Switchable Passive Probe (200 MHz when 10X is selected).
P6101B - 1X passive probe (15 MHz, 300 VRMS CAT II rating).
P6015A - 1000X high voltage passive probe (75 MHz).
P5100 - 100X high voltage passive probe (75 MHz).
P5200 - High voltage active differential probe (25 MHz).
P6021 - 15 A, 60 MHz AC current probe.
P6022 - 6 A, 120 MHz AC current probe.
A621 - 2000 A, 5 to 50 kHz AC current probe.
A622 - 100 A, 100 kHz AC/DC current probe/BNC.
TCP303/TCPA300 - 15 A, 15 MHz AC/DC current probe/amplifier.
TCP305/TCPA300 - 50 A, 50 MHz AC/DC current probe/amplifier.
TCP312/TCPA300 - 30 A, 100 MHz AC/DC current probe/amplifier.
TCP404XL/TCPA400 - 500 A, 2 MHz AC/DC current probe/amplifier.
Service Options *4
Opt. C3 - Calibration Service 3 Years.
Opt. C5 - Calibration Service 5 Years.
Opt. D1 - Calibration Data Report.
Opt. D3 - Calibration Data Report 3 Years (with Option C3).
Opt. D5 - Calibration Data Report 5 Years (with Option C5).
Opt. CA1 - Provides a single calibration event or coverage for the designated calibration interval, whichever comes first.
*4 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.
Service Offerings (available after purchase)
TDSxxxxB-CA1 - Provides a single calibration event or coverage for the designated calibration interval, whichever comes first.
The Complete Measurement Solution
The AFG3000 Series arbitrary function generator pairs with the TDS2000B and TDS1000B Series digital storage oscilloscopes to deliver the two elements of a complete measurement solution - stimulus and acquisition. This instrument combines the capabilities of a function generator with the power of an arbitrary waveform generator, offering the performance needed to accurately verify, validate, and characterize designs with ease and confidence at a price you can afford.
The Tektronix Customer Service Advantage
You can trust Tektronix to offer unequalled engineering expertise and a customer-centric approach to ensure the optimal performance of your Tektronix products and maximize the lifetime value of your Tektronix investment. With service from Tektronix you get:
- • Access to the source of product knowledge; unsurpassed technical expertise
- • Your challenges solved via front-line technical experts, design engineering reinforcement and online support tools
- • Comprehensive and thorough support provided worldwide, including software and firmware updates, data reports and adjustments
- • Efficiency and convenience; no hassle service from initial service call to turnaround and delivery
- • Flexible repair and calibration service with access to the best on-call technical trouble shooting staff in the industry, with over 20 years of training per support engineer
- • Customer-centric approach dedicated to serving your needs everyday with services designed to optimize your product performance, increase productivity and ROI by delivering a fixed cost of ownership, and efficient management of service
|
| Product(s) are manufactured in ISO registered facilities.
|
| Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. |