GDS-820S digital oscilloscope GDS-820S
产品简介
The GDS-820S 150MHz Digital Storage Oscilloscopes have monochrome LCD displays with a balanced performance and comprehensive standard features designed to meet the flexible needs demanded from a moder
产品详细信息
| GDS-820S digital oscilloscope FEATURES |
|
| GDS-820S digital oscilloscope SPECIFICATIONS |
DISPLAY SYSTEM | |
| Display Device | Mono (320 x 240) 5.7 inch LCD |
| Display Contrast | Adjustable |
| Waveform Display Graticule | 8×10 divisions ( 8 x 12 div, when menu off ) |
| Display Mode | Dot, Vector, Accumulate |
VERTICAL SYSTEM | |
| Bandwidth | 150MHz |
| Channels | 2 |
| Vertical Resolution | 8-Bit |
| Vertical Sensitivity | 2mV/div ~ 5V/div |
| Vertical Accuracy | ±3% |
| Rise Time | <2.3ns |
| Input Coupling | AC、DC、Ground |
| Input Impedance | 1MΩ ±2%, ~ 22pF |
| Polarity | Positive & Negative |
| Maximum Voltage Between Signal & Common at Input BNC | 300V ( DC+AC peak ), CATII |
| Waveform Signal Process | CH1+CH2、CH1-CH2、FFT |
| Offset Range | 2mV/div ~ 50mV/div:±0.5V 100mV/div ~ 500mV/div:±5V 1V/div ~ 5V/div:±50V |
| BW Limit | 20MHz ( -3dB ) |
HORIZONTAL SYSTEM | |
| Time Base Range | 1ns/div ~ 10s/div ; Roll : 250ms/div~10s/div |
| Time Base Mode | Main、Window、Window Zoom、Roll、X-Y |
| Time Base Accuracy | ±0.01% |
| Delay Range | Pre-trigger : 20 div maximum; Post-trigger : 1000 div |
SIGNAL ACQUISITION SYSTEM | |
| Real-Time Sample Rate | 100MS/s maximum on each channel |
| Equivalent Sample Rate | 25GS/s E.T. maximum on each channel |
| Record Length | 125k/CH |
| Peak Detection | 10ns (500ns/div~10s/div) |
| Acquisition Mode | Sample、Peak Detect、Average |
| Average | 2, 4, 8, 16, 32, 64, 128, 256 |
TRIGGER | |
| Trigger Source | CH1, CH2, Line, Ext |
| Mode | Auto Level、Auto、Normal、Single、TV、Time Delay、Event Delay、Edge、Pulse Width |
| Coupling | AC, DC, HF, LF, Noise Reject |
| Sensitivity | DC~30MHz : 0.5div or 5mV 30MHz~150MHz : Approx 1.5div or 15mV |
X-Y MODE | |
| X-Axis Input / Y-Axis Input | Channel 1 / Channel 2 |
| Phase Shift | ±3° at 100kHz |
| CURSOR & MEASUREMENT | |
| Auto Voltage Measurement | Vpp,Vamp,Vavg,Vrms,Vhi,Vlo,Vmax,Vmin |
| Auto Time Measurement | Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
| Cursor Measurement | Voltage difference between cursors(ΔV) Time difference between cursors(ΔT) Frequency difference between cursors(1/ΔT) |
| FREQUENCY COUNTER | |
| Readout Resolution | Max. 6 digits |
| Frequency Range | AC Coupled, 20Hz to rated bandwidth; resolution : 10Hz |
| Signal Source | All available trigger source except the Pulse Width & Video Trigger mode |
| EXTERNAL TRIGGER | |
| Range | ±15V |
| Sensitivity | DC~30MHz : ~50mV ; 30~150MHz:~100mV |
| Input Impedance | 1MΩ±2%, ~ 22pF |
| Maximum Input | 300V ( DC+AC peak ) , CATII |
| CONTROL PANEL FUNCTION | |
| AutoSet | "Autoset" can adjust Vertical ( Volt/div ), Horizontal ( Sec/div ) and Trigger level automatically |
| Save/Recall | Up to 15 sets of measurement conditions can be saved and recalled |
| Waveform Trace Save/Recall | 2 sets of waveform can be saved and recalled |
| INTERFACE | |
| Standard | USB, RS-232C, Printer Port, Go/NoGo Output |
| Option | GPIB |
| POWER SOURCE | |
| 100V ~ 240V AC 47Hz ~ 63Hz, Auto selection | |
ACCESSORIES | |
| User manual x 1 Power Cord x 1 GTP-150A Probe(10:1/1:1) x 2 | |
| DIMENSIONS &WEIGHT | |
| 310(W) x 142(H) x 254(D)mm Approx. 4.1kg | |