100~240 vac(50/60hz)less than10va(except communication)multi-input(t/c:13 kinds, valtage:3 kinds)
control output
alarm
4 alarm output(al-1,2,3,4)
communication
rs 485/422(optional)
setting
display
pv:digital led, sv:lcd back light
setting and display accuracy
f.s 0.1%
setting resolution
1 or 0.1%(according to input range)
memory protection
run,reset, pattern, hold
number of pattern
1~99 time or limitless
hour,minute
sampling cycle
insulation resistance
dlelectric strength
ambent temperature&humidity
model
hy-p100
hy-p101
power voltage
100-240vac (50/60hz)
power consumption
less than 15va (except to communication option)
input
thermo couple, r·t·d, voltage/current
relay contact output: ac250v(resistive load),ssr: 12vdc(constant voltage pulse) (load resistance more than 800ヘ),current: 4ma dc (load resistance less than 500ヘ)
control action
p·i·d (auto-tuning function), on/off
alarm output
indipendent variation alarm
remote
within rs-232c
by the up/down key
by the up/down or rs-232c
setting and indication accuracy
【0.3% f·s + 1digit binput: within 0…399∩ 【(5% f·s + 1digit)
1 or 0.1 (by input range), time: 1 minute
about 10 years
external control function
run, reset, pattern no, hold
instrument accident alarm
open collector max 24vdc 50ma - off (when make an accident)
self control function
ram check, data error check, system overcrowding check
manual control
-10…+110(resolution 1%)
device control
auto-tuning, alarm setting
pattern
6 pattern
segment
16 segment
pattern contact
until max 6 pattern
operation
999 time or limitless
program
max 1/hour
500ms
reverese/direct action
be se-lected by inside switch
more than dc500v 20й(between terminal and earth),more than dc 1,000v 20й(between terminal and earth)
dielectric strength
ac 500v for 1 minute (betweeh terminal and earth)ac 1,000v for 1 minute(between terminal and earth)
ambient temperature and humidity
0…50∩(32…122⒌)·35…85%rh
ux100
appearance
din(mm)(w)】(h)】(d)
function
·multi input ·input correction ·protection(frong facia ip65)·alarm output ·auto-tuning pid ·output limit correction )·fuzzy function ·interface(rs 485) ·reverse/direct se-lectable
thermocouple: k, j, e, t, r, s, b, l, n, u.wre 5-26, pl-弗 r.t.d : pt 100目, kpt 100目 direct voltage: 1…5v,1…10v,-10…20mv,0…100mv(programmable scale type)
sampling time
250ms, (when remote option: 500ms)
cold junction temperature compensation tolerance
【1.5∩(15…35∩), 【2.0∩(0…50∩)
input impedance
t/c and mv input :1 m目 min, dc v: 1m目
lead wire tolerable resistance
r.t.d: 150目max. / wire
input tolerable voltage
【10v(t/c, r.t.d, voltage: mv dc) 【20v (voltage: v dc)
noise removal rate
standard
t/c, r.t.d: ks, iec, din
scaling
according to setting max. voltage(sh), min. value(sl) of measurement range, scaling is available(-1999…9999)
standard junction temp. compensation tolerance
burn-out
t/c : off, up/down se-lectable r.t.d: off, up/down se-lectable(detection current: 50na)
accuracy
【0.5%(full scale)