airpax 6700 series standard temperature calibrations |
|
|
|
|
|
operate |
reset |
differential |
|
|
(plus/minus 5º c) |
(minº c) |
(minº c) |
|
|
40 |
20 |
4 |
|
|
45 |
20 |
4 |
|
|
50 |
30 |
4 |
|
|
55 |
30 |
4 |
|
|
60 |
40 |
4 |
|
|
65 |
40 |
4 |
|
|
70 |
50 |
4 |
|
|
75 |
50 |
4 |
|
|
80 |
55 |
6 |
|
|
85 |
55 |
6 |
|
|
90 |
60 |
6 |
|
|
95 |
60 |
6 |
|
|
100 |
70 |
6 |
|
|
105 |
70 |
6 |
|
|
110 |
80 |
6 |
|
|
115 |
85 |
6 |
|
|
120 |
85 |
9 |
|
|
125 |
85 |
9 |
|
|
130 |
90 |
9 |
|
|
|
|
|
dimensional drawings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
packaging |
|
(standard) all samples and production orders will be shipped in plastic, industry-standard shipping tubes. |
|
|
|
|
|
|
|
|
|
how to use this chart |
|
each thermostat part number consists of functional "building blocks" to enable the user to specify clearly and precisely the desired characteristics in each category. se-lect the proper code in each category, then transfer it to the box indicated . unless a special requirement is indicated, the part number will be complete when the proper temperature is se-lected. if you have a special requirement, please call airpax for a factory assigned number to complete the part number. |
|
example: a 67f060 thermostat will close (make contact) on a rising temperature from 55º c to 65º c and will reset (break contact) on a falling temperature no less than 4º c lower than the actual close temperature and no lower than 40º c actual temperature. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ul, csa & vde file numbers: |
ul recognized e36687 |
|
|
csa certified lr25561 |
|
|
vde approval 11624, 2-4510-1004 (plastic bracket only) |
|
|