Model
|
Disposition way
|
Main technical parameter
|
Characteristic
|
MB99-1
|
Ordinary disposition (five
wraps)
|
HD-21-2, BSZ-100, HL-2, XWT-S1044, chromatographic
analysis columnthree, wave length: 220th, 254, 280, 340 nm;
Fixed time scope: 1second -24 hour. Collection capacity: 12
mlX100; Current capacity:0.1-10 ml/m
|
The combination use, the
performance is stable
|
MB99-2
|
Standard disposition (five
wraps)
|
HD-21-2, SBS-100, HL-2S, XWT-S1044, chromatographic
analysis columnthree, wave length: 220th, 254, 280, 340 nm;
Fixed time scope: 1second -24 hour. Decides the drop scope:
1-9999 drop; Collectioncapacity: 12 mlX100; Current capacity:
0.1-10 ml/m
|
MB99-3
|
Luxurious disposition (six
wraps)
|
HD-21-2, DBS-100, DHL-A, 3,057, instrument truck,
chromatographicanalysis column three, wave length: 220th,
254, 280, 340 nm; Fixedtime scope: 1 second -24 hour. Decides
the drop scope: 1-9999 drop;Collection capacity: 12 mlX100;
Current capacity: 0.1-15 ml/m
|
MD99-1
|
Ordinary disposition (five
wraps)
|
HD-21-2, BSZ-100, HL-2, HD-A, chromatographic
analysis column three,wave length: 220th, 254, 280, 340 nm;
Fixed time scope: 1 second -24hour. Collection capacity: 12
mlX100; Current capacity: 0.1-10 ml/massembles oneself the
computer to be possible to realize the computercartography;
Data analysis; Computation and
preservation.
|
MD99-2
|
Standard disposition (five
wraps)
|
HD-21-2, SBS-100, HL-2S, HD-A, chromatographic
analysis column three,wave length: 220th, 254, 280, 340 nm;
Fixed time scope: 1 second -24hour. Collection capacity: 12
mlX100; Current capacity: 0.1-10 ml/massembles oneself the
computer to be possible to realize the computercartography;
Data analysis; Computation and
preservation
|
MD99-3
|
Luxurious disposition (six
wraps)
|
HD-21-2, DBS-100, DHL-A, HD-A, instrument truck,
chromatographicanalysis column three, wave length: 220th,
254, 280, 340 nm; Fixedtime scope: 1 second -24 hour.
Collection capacity: 12 mlX100; Currentcapacity: 0.1-15 ml/m
assembles oneself the computer to be possible torealize the
computer cartography; Data analysis; Computation
andpreservation.
|
ME99-1
|
Ordinary disposition (five
wraps)
|
HD-21-2, BSZ-100, HL-2, LM17-1, CXG-1,
chromatographic analysis columnthree, wave length: 220th,
254, 280, 340 nm; Fixed time scope: 1second -24 hour.
Collection capacity: 12 mlX100; Current capacity:0.1-10 ml/m
warm controls the scope: 0-45; Chromatographic
analysiscabinet volume: 250L
|
ME99-2
|
Ordinary disposition (six wraps)
|
HD-21-2, SBS-100, HL-2S, 3057-11, CXG-1,
chromatographic analysiscolumn three, wave length: 220th,
254, 280, 340 nm; Fixed time scope:1 second -24 hour. Decides
the drop scope: 1-9999 drop; Collectioncapacity: 12 mlX100;
Current capacity: 0.1-10 ml/m warm controls thescope: 0-45;
Chromatographic analysis cabinet volume:
250L
|
ME99-3
|
Ordinary disposition (five +1
wraps)
|
HD-21-2, DBS-100, DHL-A, CXG-1, chromatographic analysis
column three,wave length: 220th, 254, 280, 340 nm; Fixed time
scope: 1 second -24hour. Decides the peak scope: 0-1 00 mv;
Collection capacity: 12mlX100; Current capacity: 0.01-15 ml/m
warm controls the scope: 0-45;Chromatographic analysis
cabinet volume: 250L assembles oneself thecomputer to be
possible to realize the computer cartography; Dataanalysis;
Computation and preservation |